3M 8800-APC/AS/AGC Instructions Manual

3M 8800-APC/AS/AGC Instructions Manual

No polish connector

Advertisement

Quick Links

3M
No Polish Connector
8800-APC/AS/AGC SM SC/APC,
AGC Angle Splice, 250/900 μm
Using 3M
Angle Fiber Cleaver
2536-AGC
Instructions
April 2018
78-0015-4562-9-A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8800-APC/AS/AGC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for 3M 8800-APC/AS/AGC

  • Page 1 No Polish Connector ™ 8800-APC/AS/AGC SM SC/APC, AGC Angle Splice, 250/900 μm Using 3M Angle Fiber Cleaver ™ 2536-AGC Instructions April 2018 78-0015-4562-9-A...
  • Page 2: Table Of Contents

    Contact a physician . Upon skin contact, wash with soap and water . Product Information: Safety Data Sheet (SDS) or 3M Company, St . Paul MN, 55144-1000, (651) 733-1110 Operator 55...
  • Page 3: Summary

    78-0015-4562-9-A April 2018 1 .2 Required tools, which are available in the 3M Fiber ™ Optic Angle Cleave Kit 8865-AGC . a . Fiber shard container b . 3M Angle Fiber ™ Cleaver 2536-AGC c . 3M No Polish ™...
  • Page 4: Connector Preparation

    . Step 4 .3-4 . 7 place 3 .2 Open the actuator button on the assembly tool base . Insert a 3M No Polish Connector into the fiber into the fiber holder groove, labeled ™...
  • Page 5 78-0015-4562-9-A April 2018 4 .3 Use the left edge of the cleaver to determine the 4 .6 Clean fiber with alcohol and lint-free cloth . 1 .38 in . (35 mm) strip length of the 900 µm and 250 µm coatings . 1 .38"...
  • Page 6 April 2018 78-0015-4562-9-A 4 .8 Ensure the funnel is in the forward-most position . 4 . 1 1 Latch the clamp to secure the fiber in position . 4 .9 Lay the fiber into the fiber holder tool and close all 4 .
  • Page 7: Fiber Insertion

    78-0015-4562-9-A April 2018 4 . 1 5 Depress cleave activation lever . 5 .2 Place fiber holder in the assembly tool base . 5 .3 VERY SLOWLY slide the fiber holder towards the 4 . 1 6 Verify the 8 mm cleave length again by using the length gauge on the assembly base .
  • Page 8: Splice Actuation

    6 .4 Slide fiber holder from actuation tool . form this step now. Do not proceed to step 6.2 until testing is complete. If re-termination is required, please skip to Section 7, 3M No Polish Connector ™ (NPC) Re-termination. Optional: 3M No Polish Connector can be tested in the ™...
  • Page 9: Connector Re-Termination

    For information regarding the proper field testing activating the buffer clamp at the boot . Take procedure refer to the Tech Tip on the 3M CMD website, the cap popper provided for you in the box of www.3M.com/Telecom.
  • Page 10 Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of one (1) year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

This manual is also suitable for:

8865-agc2536-agc8865-at

Table of Contents