Troubleshooting - SATA SATAjet X 5500 Operating Instructions Manual

Hide thumbs Also See for SATAjet X 5500:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 467
Operating Instructions SATAjet X 5500 RP/HVLP (DIGITAL)
US
Tighten locking screw [10-1] (Torx TX20) with max. 1 Nm – while
holding down button
9.7. Replacing the Battery (DIGITAL)
• Replace the battery outside of explosive areas only!
• Strictly observe the safety instructions in chapter 6.4.2!
• Do not open the digital unit cover plate [11-3]! Any warranty claims
are void if these instructions are not adhered to!
According to the intensity of use, the battery will last between 1 to 3
years. To exclude measurement errors, the display will be shut-off in case
of insufficient battery capacity. According to display and use, the battery
has to be exchanged within the following time frames:
Display:
Battery symbol
Exclamation points (flashing)
Display "Lo
crew in new battery compartment lid with pre-mounted sealing (Art. No.
1057414 including battery) hand-tight and check function.

10. Troubleshooting

Malfunction
Fluttering/spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
Air bubbles appearing
in the gravity flow cup
478
Danger! Risk of explosion!
" upon switching-on
b
Cause
Fluid tip has not been
properly tightened
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
4-5 weeks
2-3 weeks
<1 week
Corrective action
Tighten fluid tip [2-1]
with universal spanner
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
[11-1] and [11-2]

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents