9.7. Replacing the battery (DIGITAL)
• Exchange battery outside of explosive areas only!
• Strictly observe the safety instructions in chapter 6.4.2!
According to the intensity of use, the battery will last between 1 to 3 years.
If the battery symbol appears on the pressure display, the battery has to
be exchanged within the next 2 to 3 weeks. The battery is empty when
no pressure is indicated with the spray gun inlet pressure exceeding 0.2
bar / 3 psi (trigger fully pulled). Tighten new battery lid with pre-assembled
sealing (Art. No. 133884 including battery) and check functionality.

10. Troubleshooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
126
Warning! Risk of explosion!
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
[12-1] and [12-2]
Corrective Action
Tighten fluid tip
[2-1]
with universal
spanner
Replace air distribu-
tion ring, as it will be
damaged during disas-
sembly