Cleaning The Spray Gun - SATA SATAjet X 5500 Operating Instructions Manual

Hide thumbs Also See for SATAjet X 5500:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 467
Operating Instructions SATAjet X 5500 RP/HVLP (DIGITAL)
US
rate method).
7.2. Adjustment of the Material Flow
und [4-4] - material flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
7.3. Adjustment of the Spray Fan Pattern
• Adjust flat fan (factory setting) [5-1].
• Adjust round fan [5-2].
7.4. Painting
Fully pull trigger for painting [6-1]. Operate spray gun according to [6-2].
Maintain spray distance as described in chapter 2.
8.

Cleaning the Spray Gun

• Prior to cleaning, please disconnect the spray gun from the com-
pressed air circuit!
• Risk of injury due to unexpected leakage of compressed air or mate-
rial!
• Empty spray gun and gravity flow cup completely, dispose of paint
material appropriately!
• Disassemble and install components very carefully! Exclusively use
included special tools!
• Use neutral cleaning solution (pH value 6 to 8)!*
• Do not use acids, alkalines, bases, pickling agents, unsuit-
able regenerates or other aggressive cleaning solutions!*
• Do not soak spray gun in cleaning solution! *Cleaning solution
must never penetrate the air passages!
• Do not clean cover plate of the electronic pressure display with point-
ed, sharp or rough objects!
474
Information!
Danger! Notice!
[4-1], [4-2], [4-3]

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents