Technical Data

General
Typical Measuring Tolerance* ± 1.0 mm / ~1/16" ***
Maximum Measuring
Tolerance**
Range at Leica target plate
GZM26
Typical Range*
Range at unfavourable
condition ****
Smallest unit displayed
Power Range Technology
Laser class
Laser type
Ø laser point
at distances
Protection class
Autom. laser switch off
Autom. power switch-off
Battery durability (2 x AAA)
Dimension (H x D x W)
Weight (with batteries)
Temperature range:
- Storage
- Operation
* applies for 100 % target reflectivity (white painted wall),
low ambient light, 25 ºC
** applies for 10 to 500 % target reflectivity, high ambient
light, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence
level of 95%. The maximum tolerance may deteriorate to
0.1 mm/m between 10 m to 30 m and to 0.20 mm/m for
distances above 30 m
**** applies for 100 % target reflectivity, background illumi-
nation of approximately 30'000 lux
Leica DISTO
TM
E7300 788218a
Find Quality Products Online at:
Functions
Distance measuring
± 2.0 mm / 0.08 in ***
Min/Max measuring
Permanent measuring
100 m / 328 ft
Stake-out
Addition/Subtraction
0.05-80 m / 230 ft
Area
50 m / 164 ft
Volume
0.1 mm / 1/32 in
Painter function (area with
yes
partial measurem.)
2
Pythagoras
635 nm, < 1 mW
Memory
6 /30 / 60 mm
Beep
10 / 50 / 100 m
Illuminated display
IP54 (dust- and splash
Automatic multifunctional
water protected)
endpiece
after 90 s
after 180 s
up to 5000 measure-
ments
114 x 50 x 27 mm
4.49 x 1.97 x 1.06 in
126 g / 4.05 oz
-25 to 70 °C
-13 to 158 °F
-10 to 50 °C
14 to 122 °F
GlobalTestSupply
www.

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
yes
contact the dealer.
yes
If the message InFo appears with a number,
yes
press the Clear button and observe the
yes
following instructions:
yes
yes
No.
Cause
yes
204
Calculation error
yes
252
Temperature too high
2-point and 3-point
253
Temperature too low
10 results
255
Received signal too
yes
weak, measuring time
yes
too long
yes
256
Received signal too high
257
Too much background
light
258
Measurement outside of
measuring range
260
Laser beam interrupted
.com
Correction
Perform measurement
again.
Let device cool down.
Warm device up.
Change target surface
(e.g. white paper).
Change target surface
(e.g. white paper).
Shadow target area.
Correct range.
Repeat measurement.