Advertisement

Leica DISTO
D2
TM
The original laser distance meter

Advertisement

Table of Contents
loading

Summary of Contents for Leica DISTO D2

  • Page 1 Leica DISTO The original laser distance meter...
  • Page 2: Table Of Contents

    Overview Technical data Instrument Set-up Operations Message Codes Care Warranty Safety instructions Leica DISTO™ D2...
  • Page 3: Overview

    Overview Ov e r v i e w The Leica DISTO™ is a laser distance meter oper- 6  Clear/ OFF ating with a class 2 laser. See chapter Technical data for scope of use. 7  Memory/ Timer 8  Bluetooth® Smart 9  Subtract 1  Display 2  ON/ Measure 3  Add...
  • Page 4: Technical Data

    *** Tolerances apply from 0.05 m to 5 m with a confidence level of 95%. With favourable conditions the tolerance may deteriorate by 0.10 mm/m for distances above 5 m. With unfavourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m. Leica DISTO™ D2...
  • Page 5 Technical data Functions Distance measuring Min/Max measuring Permanent measuring Stake out Addition/Subtraction Area Volume Painter function (area with partial measurem.) Pythagoras 2-point, 3-point Memory 10 results Beep Illuminated display Automatic multifunctional endpiece Bluetooth® Smart Leica DISTO™ D2...
  • Page 6: Instrument Set-Up

    Indicates a potentially hazardous situ- understand these directions and ation or an unintended use which, if adhere to them. not avoided, may result in minor injury and/or appreciable material, financial and environmental damage. The symbols used have the following meanings: Leica DISTO™ D2...
  • Page 7 Instrument Set-up Insert batteries To ensure a reliable use, we recom- mend using high quality Alkaline bat- teries. Change batteries when battery symbol is flashing. Leica DISTO™ D2...
  • Page 8 Instrument Set-up Switching ON/OFF Device is turned OFF. Leica DISTO™ D2...
  • Page 9 Instrument Set-up Clear Undo last action. Leave actual function, go to default operation mode. Leica DISTO™ D2...
  • Page 10 Instrument Set-up Message Codes If the message "i" appears with a number, observe the instruc- tions in Message Codes section. Example: Leica DISTO™ D2...
  • Page 11 Instrument Set-up Adjusting measuring reference Press button 2 sec and ref- erence from front is set per- manently. Distance is measured from the front of the device. Distance is measured from the rear of the device (standard setting). Leica DISTO™ D2...
  • Page 12 Instrument Set-up Multifunctional endpiece The orientation of the endpiece is automatically detected and the zero point is adjusted accord- ingly. Leica DISTO™ D2...
  • Page 13 Instrument Set-up Unit setting 0.000 m 0.00 ft 0.0000 m 0'00" 1/32 0.000 in 0 in 1/32 Press both keys simultaneousley. Switch between the following units: Leica DISTO™ D2...
  • Page 14 Instrument Set-up Beep Press both keys simultaneousley. Leica DISTO™ D2...
  • Page 15: Operations

    Aim active laser at target. Target surfaces: Measuring errors can occur when meas- uring to colourless liquids, glass, styrofoam or permeable sur- faces or when aiming at high gloss surfaces. Against dark Leica DISTO™ D2...
  • Page 16 Used to measure room diagonals Stops permanent / minimum-max- (maximum values) or horizontal dis- imum measuring. tance (minimum values). The min- imum and maximum distance measured is displayed (min, max.). The last value measured is displayed in the main line. Leica DISTO™ D2...
  • Page 17 In this case press DIST to show the result. The next measurement is added to the previous one, respectively sub- tracted from the previous one. Leica DISTO™ D2...
  • Page 18 The result is shown in the main line and the measured value above. Painter function: Press + or - after starting the first meas- Circumference is displayed. urement. Measure and add or subtract wall lengths. Measure Leica DISTO™ D2...
  • Page 19 Operations Volume Aim laser at first target point. Aim laser at second target point. Aim laser at third target point. Circumference and wall area are dis- played. Leica DISTO™ D2...
  • Page 20 Operations Memory (last 10 results) Last 10 values are displayed. Navigates through last 10 values. Leica DISTO™ D2...
  • Page 21 Operations Delete Memory Press both keys simultaneousley. Memory is completely deleted. Leica DISTO™ D2...
  • Page 22 It avoids shak- ing of the device when pressing the measurement key. Adjust delay of automatic release (max. 60 sec, standard setting = 5 sec.). Once the key is released with Leica DISTO™ D2...
  • Page 23 Aim laser at upper point. Aim laser rectangular at lower point. The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the function activ- ates automatically Minimum or Maximum measurement. Leica DISTO™ D2...
  • Page 24 Aim laser at rectangular point. Maximum measurement. Aim laser at lower point. The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the function activ- ates automatically Minimum or Leica DISTO™ D2...
  • Page 25 Move device slowly along the stake 0.240m is missing up to next 0.625m out line. The distance to the next distance. stake out point is displayed. When approaching a stake out point to less then 0.1 m the Leica DISTO™ D2...
  • Page 26 A wide range of com- mercial software can be found on our homepage. Apps for Android® or iOS can be found in special internet shops. For more details, see our homepage. Leica DISTO™ D2...
  • Page 27: Message Codes

    Received signal too high Change target surface (e.g. white paper) . Too much background light Shadow target area. * If other message codes are displayed frequently even the instrument has been switched off and on, please contact your dealer. Leica DISTO™ D2...
  • Page 28: Care

    Care Ca r e Clean the device with a damp, soft cloth. Never immerse the device in water. Never use aggressive cleaning agents or solvents. Leica DISTO™ D2...
  • Page 29: Warranty

    Warranty under PROTECT by Leica Geosystems Lifetime Manufacturer´s Warranty Warranty coverage for the entire usage time of the product under PROTECT according to Leica Geosystems International Limited Warranty and PROTECT General Terms & Conditions set out under www.leica-geosystems.com. Free of...
  • Page 30: Safety Instructions

    Safety instructions Sa f e t y i n s t r u c t i o n s The person responsible for the instrument must ensure that all users understand these directions and adhere to them. Leica DISTO™ D2...
  • Page 31 CAUTION Indicates a potentially hazardous situation or an unintended use which, if not avoided, may result in minor injury and/or appreciable material, financial and environmental damage. Leica DISTO™ D2...
  • Page 32 Safety instructions Permitted use Measuring distances Data transfer with Bluetooth® Leica DISTO™ D2...
  • Page 33 (e.g. when measuring on roads, con- struction sites, etc.) Deliberate or irresponsible behaviour on scaffolding, when using ladders, when measuring near machines which are run- ning or near parts of machines or install- ations which are unprotected Aiming directly in the sun Leica DISTO™ D2...
  • Page 34 CAUTION Never attempt to repair the product yourself. In case of damage, contact a local dealer. WARNING Changes or modifications not expressly approved could void the user´s authority to operate the equipment. Leica DISTO™ D2...
  • Page 35 Safety instructions Limits of use Refer to section Technical data. The device is designed for use in areas permanently hab- itable by humans. Do not use the product in explosion hazardous areas or in aggressive environments. Leica DISTO™ D2...
  • Page 36 Safety instructions Areas of responsibility Responsibilities of the manufacturer of the ori- ginal equipment: Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Internet: www.leica-geosystems.com The company above is responsible for supplying the product, including the User Manual in a com- pletely safe condition.
  • Page 37 Dispose of the product appropriately in accordance with the national regulations in force in your country. Adhere to the national and coun- try specific regulations. Product specific treatment and waste man- agement can be downloaded from our homepage. Leica DISTO™ D2...
  • Page 38 Japanese Radio Law Compliance This device is granted pursuant to the Japanese Radio Law 電 波 法 . This device should not be modified otherwise the granted designation num- ber will become invalid. Leica DISTO™ D2...
  • Page 39 Consult the dealer or an experienced radi- o/TV technician for help This instrument complies with part 15 of the FCC rules. Operation is subjected to the following two conditions: This instrument may not cause harmful interference, and Leica DISTO™ D2...
  • Page 40 Do not use the product near medical equipment. Do not use the product in airplanes. Do not use the product near your body for extended periods. Leica DISTO™ D2...
  • Page 41 Looking directly into the beam with optical aids (e.g. binoculars, telescopes) can be hazardous. CAUTION Looking into the laser beam may be hazardous to the eyes. Wavelength 620 - 690 nm Maximum radiant output power for classification < 1 mW Leica DISTO™ D2...
  • Page 42 Safety instructions Labelling Subject to change (drawings, descriptions and technical data) without prior notice. Leica DISTO™ D2...

Table of Contents