Appendix; Technical Data - Leica DISTO D5 User Manual

Disto d5 laser distance meter
Hide thumbs Also See for DISTO D5:
Table of Contents

Advertisement

Technical data

Distance measurements:
Measuring accuracy up to 10 m
(2 σ, standard deviation)
Power Range Technology™:
Range (use target plate from about 100 m)
Smallest unit displayed
Distance measurement
Minimum/maximum measurement, Conti-
nuous measurement
Area/volume calculation of room data
Addition / subtraction
Indirect measurement using
Pythagoras
Trapezium measurement
Tilt measurements:
Tilt sensor:
Accuracy (2 σ, standard deviation)
- to laser beam
- to the housing
Indirect measurement using tilt sensor
(direct horizontal distance)
Angle measurement using tilt sensor
(± 45°)
General:
Laser class
Laser type
Ø laser point
(at distances)
Autom. laser switch-off
Autom. instrument switch-off
Display illumination
Multifunctional endpiece
Timer (self-triggering)
Leica DISTO™ D5 766548a gb
Save constant value
Historical storage
Tripod thread (Type: 1/4-20)
typically: ± 1.0 mm*
Battery life,
Type AA, 2 x 1.5V
0.05 m to 200 m
Protection against splashes and dust
0.1 mm
Dimensions
Weight (with batteries)
Temperature range:
Storage
Operation
* maximum deviation occurs under unfavourable conditions such as bright sunlight or
when measuring to poorly reflecting or very rough surfaces. Measuring accuracy
between 10 m and 30 m may deteriorate to approx. ± 0.025 mm/m, for distances
above 30 m to ± 0.1 mm/m. In long range mode the maximum deviation from a
distance of 30 m increases to +/- 0.15 mm/m.
± 0.3°
Measuring conditions
± 0.3°
Measuring range
The range is limited to 200 m.
At night or dusk and if the target is in shadow the measuring range without
target plate is increased. Use a target plate to increase the measurement
II
range during daylight or if the target has poor reflection properties.
635 nm, < 1 mW
Target surfaces
6 / 30 / 60 mm
(10 / 50 / 100 m)
Measuring errors can occur when measuring toward colourless liquids (e.g.
after 3 min
water) or dust free glass, Styrofoam or similar semi-permeable surfaces.
after 6 min
Aiming at high gloss surfaces may deflect the laser beam and lead to
measurement errors.
Against non-reflective and dark surfaces the measuring time may increase.
15
D
20 values
GB
F
up to
5 000 measurements
I
IP 54, dust-proof,
E
splash-proof
P
143.5 x 55 x 30 mm
195 g
NL
CN
-25°C up to +70°C
(-13°F up to +158°F)
N
-10°C up to +50°C
S
(14°F up to +122°F)
FIN
DK
SLO
TR
GR
ROK
RUS
SK
CZ
H
PL
EST
LT
LV

Appendix

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents