Technical Data

Distance measurement
Typical Measuring Tolerance* ± 1.0 mm / ~1/16" ***
Maximum Measuring
± 2.0 mm / 0.08 in ***
Tolerance**
Typical Range*
200 m / 660 ft
Range at unfavourable
80 m / 260 ft
condition ****
Smallest unit displayed
0.1 mm / 1/32 in
Power Range Technology
yes
Ø laser point
6 /30 / 60 mm
at distances
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser
-0.1° / +0.2°
beam*****
Measuring tolerance to
± 0.1°
housing*****
Range
360°
General
Laser class
2
Laser type
635 nm, < 1 mW
Protection class
IP54 (dust- and splash
water protected)
Autom. laser switch off
after 90 s
Autom. power switch-off
after 180 s
®
Bluethooth
Smart
Bluethooth v4.0
®
Range of Bluethooth
10 m
Dimension (H x D x W)
61 x 31 x 164 mm
2.4 x 1.2 x 6.5 in
Weight
238 g / 8.4 oz
Temperature range:
- Storage
-25 to 70 °C
-13 to 158 °F
- Operation
-10 to 50 °C
14 to 122 °F
- Charging
-10 to 40 °C
14 to 104 °F
TM
Leica DISTO
D810 touch 799093
Photos / Screenshots
Resolution for photos
900 x 800 dpi
Resolution for screenshots
240 x 400 dpi
File format
JPG
Download of gallery
USB
Battery (Li-Ion)
Rated voltage
3.7 V
Capacity
2.6 Ah
Measurements per battery
Approx. 4000
charge
Charging time
Approx. 4 h
Output voltage
5.0 V
Charging current
1 A
* applies for 100 % target reflectivity (white painted wall),
low background illumination, 25 ºC
** applies for 10 to 100 % target reflectivity, high background
illumination, - 10 ºC to + 50 ºC
*** Tolerances apply from 0.05 m to 10 m with a confidence
level of 95%. The maximum tolerance may deteriorate to
0.1 mm/m between 10 m to 30 m, to 0.20 mm/m between
30 m to 100 m and to 0.30 mm/m for distances above 100 m
**** applies for 100 % target reflectivity, background illumi-
nation of approximately 30'000 lux
***** after user calibration. Additional angle related devia-
tion of +/- 0.01° per degree up to +/-45° in each quadrant.
Applies at room temperature. For the whole operating
temperature range the maximum deviation increases by
+/-0.1°.
At a recommended storage tempera-
ture of -20°C to +30°C (-4°F to
+86°F), batteries containing a 50% to 100%
charge can be stored up to 1 year. After this
storage period the batteries must be
recharged.
For accurate indirect results, the use of
a tripod is recommended. For accurate
tilt measurements a transverse tilt should be
avoided.