Technical data

T e c h n i c a l d a t a
General
Accuracy with favourable conditions *
Accuracy with unfavourable conditions **
Range with favourable conditions *
Range with unfavourable conditions **
Smallest unit displayed
X-Range Power Technology
Laser class
Laser type
ø laser point | at distances
Protection class
Auto. laser switch off
Auto. power switch off
Bluetooth® Smart
Range of Bluetooth® Smart
Battery durability (2 x AAA)
Dimension (H x D x W)
Weight (with batteries)
Temperature range Storage | Operation
* favourable conditions are: white and diffuse reflecting target (white painted wall), low background illumination and moderate temperatures.
** unfavourable conditions are: targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range.
*** Tolerances apply from 0.05 m to 5 m with a confidence level of 95%.
With favourable conditions the tolerance may deteriorate by 0.10 mm/m for distances above 5 m.
With unfavourable conditions the tolerance may deteriorate by 0.15 mm/m for distances above 5 m.
Leica DISTO™ D2
1.5 mm / 1/16" ***
3 mm / 1/8" ***
0.05 - 100m / 0.16 - 330ft ***
0.05 - 60m / 0.16 - 200ft ***
0.1 mm / 1/32 in
yes
2
635 nm, <1 mW
6 /30 /60 mm | 10/ 50/ 100 m
IP54 (dust- and splash water protected)
after 90 s
after 180 s
Bluetooth® v4.0
<10m
up to 10000 measurements
116 x 44 x 26 mm | 4.57 x 1.73 x 1.02 in
100 g/ 3.53 oz
-25 to 70°C/ -13 to 158°F | -10 to 50°C/ 14 to 122°F