5.6 - Electrical data notes for the hydraulic module

The pumps fitted to these units have motors which meet efficiency class IE2 for motors < 7.5kW and IE3 for motors > 7 .5kW.
The additional electrical data required
For the low-pressure single pump motors of 30RBM/RBP 160-520 units (option 116T)
No.
Description
(2)
(3)
1
Nominal efficiency at full load and nominal voltage
1
Nominal efficiency at 75% of full load and nominal voltage
1
Nominal efficiency at 50% of full load and nominal voltage
2
Efficiency level
3
Year of manufacture
4
Manufacturer's name and trademark, commercial registration
number and manufacturer's head office
5
Product's model number
6
Number of motor poles
7-1
Nominal shaft power output at full load and nominal voltage (400 V)
7-2
Maximum input power (400 V)
8
Rated input frequency
9-1
Nominal voltage
9-2
Maximum current drawn (400 V)
10
Nominal speed
11
Product disassembly, recycling or disposal at end of life
12
Operating conditions for which the motor is specifically designed
I- Altitudes above sea level
II - Ambient air temperature
IV - Maximum operating temperature
V - Potentially explosive atmospheres
(1) Required by regulation No. 640/2009 concerning the application of directive 2009/125/EC on the eco-design requirements for electric motors.
(2) Item number imposed by regulation No. 640/2009, annex I2b.
(3) Description given by regulation No. 640/2009, annex I2b.
(4) To obtain the maximum input power for a unit with hydraulic module, add the maximum unit input power from the electrical data table to the pump power input.
(5) To obtain the maximum operating current draw for a unit with hydraulic module, add the maximum unit current draw from the electrical data table to the pump current draw.
(6) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.
For the low-pressure dual pump motors of 30RBM/RBP 160-520 units (option 116U)
No.
Description
(2)
(3)
1
Nominal efficiency at full load and nominal voltage
1
Nominal efficiency at 75% of full load and nominal voltage
1
Nominal efficiency at 50% of full load and nominal voltage
2
Efficiency level
3
Year of manufacture
4
Manufacturer's name and trademark, commercial registration
number and manufacturer's head office
5
Product's model number
6
Number of motor poles
7-1
Nominal shaft power output at full load and nominal voltage (400 V)
7-2
Maximum input power (400 V)
8
Rated input frequency
9-1
Nominal voltage
9-2
Maximum current drawn (400 V)
10
Nominal speed
11
Product disassembly, recycling or disposal at end of life
12
Operating conditions for which the motor is specifically designed
I- Altitudes above sea level
II - Ambient air temperature
III - Maximum operating temperature
V - Potentially explosive atmospheres
(1) Required by regulation No. 640/2009 concerning the application of directive 2009/125/EC on the eco-design requirements for electric motors.
(2) Item number imposed by regulation No. 640/2009, annex I2b.
(3) Description given by regulation No. 640/2009, annex I2b.
(4) To obtain the maximum input power for a unit with hydraulic module, add the maximum unit input power from the electrical data table to the pump power input.
(5) To obtain the maximum operating current draw for a unit with hydraulic module, add the maximum unit current draw from the electrical data table to the pump current draw.
(6) Above 1000 m, a degradation of 3% for each 500 m should be taken into consideration.
is as follows:
(1)
(4)
(5)
(4)
(5)
Units
160
180
200
%
85,7
85,7
85,7
%
86,9
86,9
86,9
%
86,4
86,4
86,4
-
-
This information varies depending on the manufacturer and model at the time of
incorporation. Please refer to the motor nameplates.
-
-
-
2
2
2
kW
2,2
2,2
2,2
kW
2,80
2,80
2,80
Hz
50
50
50
V
3 X 400
A
4,92
4,92
4,92
rps - rpm
48 - 2900
-
Disassembly using standard tools. Disposal and recycling using an appropriate
m
°C
°C
Please refer to the operating conditions given in this manual or
in the specific conditions given in the Carrier selection programs.
-
Units
160
180
200
220
%
84,9
84,9
85,7
85,7
%
86,4
86,4
86,9
86,9
%
85,9
85,9
86,4
86,4
-
-
This information varies depending on the manufacturer and model at the time of
incorporation. Please refer to the motor nameplates.
-
-
-
2
2
2
kW
1,5
1,5
2,2
kW
1,94
1,94
2,80
2,80
Hz
50
50
50
V
A
3,41
3,41
4,92
4,92
rps - rpm
-
Disassembly using standard tools. Disposal and recycling using an appropriate
m
°C
°C
Please refer to the operating conditions given in this manual or
in the specific conditions given in the Carrier selection programs.
-
30RBM/30RBP
220
260
300
330
360
85,7
85,7
87,5
87,5
87,5
86,9
86,9
88,2
88,2
88,2
86,4
86,4
87,5
87,5
87,5
IE3
Same as above
Same as above
2
2
2
2
2
2,2
2,2
3
3
3
2,80
2,80
3,81
3,81
3,81
50
50
50
50
50
4,92
4,92
6,81
6,81
6,81
company.
< 1000
(6)
< 40
Non ATEX environment
30RBM/30RBP
260
300
330
360
87,5
87,5
87,5
87,5
88,2
88,2
88,2
88,2
87,5
87,5
87,5
87,5
IE3
Same as above
Same as above
2
2
2
2
2
2,2
3
3
3
3
3,81
3,81
3,81
3,81
50
50
50
50
50
3 X 400
6,81
6,81
6,81
6,81
48 - 2900
company.
< 1000(6)
< 40
Non ATEX environment
400
430
470
520
89,9
89,9
89,9
89
90,4
90,4
90,4
90
89,6
89,6
89,6
89,7
2
2
2
2
4
4
4
5,5
4,96
4,96
4,96
6,80
50
50
50
50
8,27
8,27
8,27 11,30
400
430
470
520
89,9
89,9
89,9
89
90,4
90,4
90,4
90
89,6
89,6
89,6
89,7
2
2
2
2
4
4
4
5,5
4,96
4,96
4,96
6,80
50
50
50
50
8,27
8,27
8,27 11,30
21