Installation (Continued):
Plumbing (Continued):
Water Inlet, Outlet Connections:
When tightening all connections on this unit, be sure to support the internal plastic piping as close as
possible to the plumbing connections, to prevent excessive torque or strain from being applied to the
internal plumbing of the unit.
The various plastic piping connections available (Unions, Flared tube fittings, etc) do not require very
much force to properly seal. Once the plumbing connections have been made, test the connections for
possible leaks and repair any leaks as needed.
Figure 25: Support Internal Piping when Connecting Plumbing (105-156kW unit shown)
Le défaut de fixer correctement la tuyauterie en
plastique lors du serrage des raccords de
plomberie peut causer des dommages internes à
la plomberie de cet appareil. De tels dommages
ne sont pas couverts par notre garantie du
produit.
Inlet/Outlet Connections; 25mm-32mm Unions (standard)
1) Remove the access panel(s) from the rear of the unit, exposing the internal plumbing and heater
column(s). The inlet plumbing will be located just below the bottom of the access panel, and the
outlet plumbing will be located just above the access panel (See figure 22).
2) Remove the sealing cap from plumbing connection.
3) Test fit the piping to ensure proper length.
4) Support the internal piping to avoid any damage during plumbing.
5) Attach the o-ring (supplied with accessories) to the male side of the union.
6) Orient the male 25mm union half so the threads can be engaged into the female 25mm union half
(nut) of the fitting.
7) Attach the male and female union halves to create the inlet connection and tighten the union
halves securely, until the connections are fully tightened.
M-43-25
Revision - Date 03-01-04-18
Failure to properly secure the plastic piping when
tightening the plumbing connections may result in
internal damage to the plumbing of this unit. Such
damage is not covered under our product warranty.