Download Print this page

Wexiodisk WD-12GHE Manual page 4

Advertisement

Available languages

Available languages

Table 1 Reference values
Left display
Text no.
01
Actual value, booster heater
02
Actual value, tank
03
Ref. value, tank
04
Ref. value booster heater programme P1
05
Ref. value booster heater programme P2
06
Ref. value booster heater programme P3
07
Wash time programme 1
08
Wash time programme 2
09
Wash time programme 3
10
Rinse time programme 1
11
Rinse time programme 2
12
Rinse time programme 3
13
Dosage time detergent
14
Delayed running time booster pump
1)
Increased rinse time gives an equivalent increase in the total wash time
Table 2 Diagnostic texts
Left display
Text no.
20
Hood breaker B1
21
Level guard P1
22
Extra input B2
23
DIP change-over switch D1
24
DIP change-over switch D2
25
DIP change-over switch D3
26
DIP change-over switch D4
1)
0=Off 1=On
Table 3
Left display
Text no.
30
Filled booster heater
31
Machine with old panel
1)
0=Unactivated 1= Activated
Table 4 Basket counting
Both displays together show the number of baskets up to 9999. By
pressing the button (3), the number of baskets will be shown in tens
of thousands.
Applies to
Applies to
Applies to
Right display
Setting area
Ref. value
-
-
o
o
60
C
30-85
o
o
85
C
30-95
85
o
C
30-95
o
o
o
85
C
30-95
1,0 min.
0-9,4 min.
3,0 min.
0,5-9,4 min.
5,0 min.
0,5-9,4 min.
13 sec.
1)
5-30 sec.
1)
13 sec.
5-30 sec.
1)
13 sec.
5-30 sec.
----
0-9,9 sec.
11 sec.
1-25 sec.
Right display
1)
0 or 1
0 or 1
1)
1)
0 or 1
0 or 1
1)
0 or 1
1)
1)
0 or 1
0 or 1
1)
NOTE! In case of emptying
Right display
the booster heater, set the
filling memory to zero (text
no. 30 in the diagnostic text
0 or 1
1)
= 0) or loosen the plug T41
1)
0 or 1
on the printed circuit card.
BV-008
2(2)
Remarks
C
C
C
C

Advertisement

loading