Adjustment of reference values
Remove the front plate of the machine.
Adjust the reference values, function change-
over etc. with the aid of the printed circuit card
(1) which is on the right side of the cubicle.
Adjustment of reference values,
diagnostic texts
1. Press 0/1 on the panel and open the hood.
2. Press the button (3) for approx. 3 sec. Text no.
01 will be displayed on the panel on the left
display. The actual value is displayed to the
right. (See table 1).
3. The texts are divided between four tables. It is
possible to change quickly between the first
rows of each table. When the text 01 is dis-
played in table 1, press +. The panel will then
display text no. 20 in table 2. If + is pressed
again, text no. 30 will be displayed in table 3 -
and so on.
4. The button (3) allows the operator to flick
forward through the texts in each table.
5. The reference values may be adjusted by
pressing + or - (4). The diagnostic texts and
reference values are shown in the tables.
6. If the diagnostic function is not to be activated
further, press the button (3) for approx. 3 sec.
Function change-over
There are 4 DIP change-over switches (2) on the
printed circuit card. The change-over switches
should be in the following positions:
DIP change-over switch 1 in ON position = Hot
water connected machine. OFF position = For
filling of cold water.
DIP change-over switch 2 in ON position =
Machine with automatic hood-lifting device (WD-
12GHE). OFF position = No automatic hood-lifting
device. (WD-12GLE)
DIP change-over switch 3 in ON position = Hood
with holding position. (Once the rinse moment is
complete, the hood is opened to a so-called
holding position. It remains in this position for
approx. 13 sec. before opening completely).
OFF position = Hood without holding position.
DIP change-over switch 4 in ON position =
Machine with emptying pump. OFF position =
Machine with booster pump.
Mårdvägen 4 S-352 45 Växjö Sweden Tel. 0470-77 12 00 Telefax 46 470 237 52
1. Printed circuit card
2. DIP change-over switches
3. Diagnostic button
4. Reference value adjustment button
Indications of error
Err1: Filling time of 8 minutes has been exceeded
without the tank being filled.
Err2: Too low water flow during filling.
Err3: The squeeze protection has disengaged.
Err4: Temperature sensor T41 faulty.
Err5: Temperature sensor T21 faulty.
Err6: Too low final rinse flow
Err7: Memory fault.
Re-setting indications of error
Err1: Press 0/1 twice.
Err2: Press 0/1 twice.
Err6: Open and close the hood.
BV-008
0108
1(2)
Rev. 1.0