UL LISTING

These merchandisers are manufactured to meet
ANSI/ UL 471 standard requirements for safety .
Proper installation is required to maintain the
listing .

FEDERAL / STATE REGULATION

These merchandisers at the time they are man-
ufactured, meet all federal and state/ provincial
regulations . Proper installation is required to
ensure these standards are maintained . Near
the serial plate, each merchandiser carries a
label identifying the environment for which the
merchandiser was designed for use .
ANSI/NSF-7 Type I – Display Refrigerator /
Freezer
Intended for 75°F (24°C) / 55%RH Ambient Application
ANSI/NSF-7 Type II – Display Refrigerator / Freezer
Intended for 80°F / 55%RH Ambient Application
ANSI/NSF-7 – Display Refrigerator
Intended for Bulk Produce
GSVM4060 and GSVM4072 are designed to perform
to Type II conditions. GSVM 5072 is designed to
perform to Type I conditions.

HUSSMANN PRODUCT CONTROL

The serial number and shipping date of all
equipment is recorded in Hussmann's files
for warranty and replacement part purposes .
All correspondence pertaining to warranty or
parts ordering must include the serial number
of each piece of equipment involved . This is to
ensure the customer is provided with the correct
parts .

SHIPPING DAMAGE

All equipment should be thoroughly examined
for shipping damage before and during
unloading . This equipment has been carefully
inspected at our factory .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

INSTALLATION

Any claim for loss or damage must be made to
the carrier . The carrier will provide any neces-
sary inspection reports and/or claim forms .

Apparent Loss or Damage

If there is an obvious loss or damage, it must
be noted on the freight bill or express receipt
and signed by the carrier's agent; otherwise,
carrier may refuse claim .

Concealed Loss or Damage

When loss or damage is not apparent until
after equipment is uncrated, retain all packing
materials and submit a written response to the
carrier for inspection within 15 days .
Recommended operating ambient
temperature is between 65°F (18°C)
to 80°F (24°C) for GSVM4060 &
GSVM 4072. 65°F (18°C) to 75°F
(24°C) for GSVM5272. Maximum
relative humidity is 55%.

LOCATION

These merchandisers are designed for
displaying products in air conditioned stores
where temperature is maintained at or below
the ANSI / NSF-7 specified level and relative
humidity is maintained at or below 55% .
Placing refrigerated merchandisers in direct
sunlight, near hot tables or near other heat
sources could impair their efficiency . Like
other merchandisers, these merchandisers are
sensitive to air disturbances . Air currents
passing around merchandisers will seriously
impair their operation . Do NOT allow air
conditioning, electric fans, open doors or
windows, etc . to create air currents around the
merchandiser .