Hussmann microSC GSVM A Series Installation & Operation Manual page 14

Medium temperature self contained open vertical merchandiser
Table of Contents

Advertisement

2-4
electrical
Before Beginning Any Service or Repair:
Use a hand-held propane leak detector ("sniffer")
to ensure no propane is present in the immediate
area, the inside of the display case and the inside
of the refrigeration system . R-290 is an odorless
refrigerant . Keep the area clear of all customers
and non-essential or unauthorized personnel .
Verify that all repair parts are identical models
to the ones they are replacing . Do not substitute
parts such as motors, switches, relays, heaters,
compressors, power supplies or solenoids .
Failure to do so can result in an explosion,
death, injury and property damage . Parts
used on hydrocarbon cases must meet specific
UL certification for non-incendive or non-
sparking components . Use only Hussmann
approved parts approved through the Hussmann
Performance Parts Website .
hussmann .com/
Brazing must not begin before all propane has
been cleared from the immediate area — the
inside of the displays case and the inside of the
refrigeration system .
If a leak is detected, follow store safety
procedures . It is the store's responsibility to have
a written safety procedure in place . The safety
procedure must comply with all applicable codes
such as local fire department's codes .
At minimum, the following actions are required:
Immediately evacuate all persons from the
store, and contact the local fire department to
advise them that a propane leak has occurred .
Call Hussmann and/or a qualified service
agent and inform them that a propane sensor has
detected the presence of propane .
Do not let any persons back into the store
until the qualified service technician has arrived
and that technician advises that it is safe to
return to the store .
P/N 3109358_B
/
refrigeration
https://parts .
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
Only Hussmann or factory
trained technicians should
service or repair this R-290
(propane) equipment.
Failure to follow
instructions can result in
an explosion, death, injury
and property damage.
The propane gas used in the unit has no odor .
The lack of smell does not indicate a lack of
escaped gas .
A hand-held propane leak detector
("sniffer") should be used before any repair and/
or maintenance is attempted . All repair parts
must be identical models to the ones they are
replacing .
No open flames, cigarettes or other possible
sources of ignition should be used inside the
building where the units are located until the
qualified service technician and/or local fire
department determines that all propane has been
cleared from the area and from the refrigeration
systems .

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microsc gsvm-4060aMicrosc gsvm-4072aMicrosc gsvm-5272a

Table of Contents