REPLACING FAN MOTORS AND
BLADES
Should it ever be necessary to service or
replace the fan motors or blades be certain
that the fan blades are reinstalled correctly .
The blades must be installed with raised
embossing (part number on plastic blades)
positioned as indicated on the parts list .
For access to these fans:
1 . Remove product and place in a refrigerated
area . Turn off power to the merchandiser .
2 . Make sure there is no voltage in the
refrigerator . Remove front grille to have
acess to the machine compartment .
3 . Remove condensing unit screws . (Fig A) .
4 . Slide out the condensing unit (Fig B) . Be
careful using the condesing unit plate to pull
out the condensing unit . Make sure not to
stress or interfere with other parts .
5 . Disconnect condenser motor harness .
6 . Release screws to remove condenser fan
assembly (Fig . C) .
7 . Release motor screws to get to motor / blade
assembly (Fig . D) .
8 . Change the failed part .
9 . If the only damaged part is the motor,
remove blade .
10 . Reverse the process and make sure
everything is in place .
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

SERVICE

Slide out condensing
unit tray by the handle as
indicated by the label.
GSVM-A Open Vertical Merchandisers