Leds; Technical Specifications; Table 6-4 Interfaces On The Rpa2161-Si-220S54 Panel; Table 6-5 Leds On The Rpa2161-Si-220S54 - Raisecom ISCOM6800 Hardware Description

Table of Contents

Advertisement

Raisecom
ISCOM6800 (A)Hardware Description

Table 6-4 Interfaces on the RPA2161-SI-220S54 panel

Interface
AC INPUT
SS-3B-6.3, 16 A/250 VAC
socket
LOAD
BTB760-00-04-01 terminal
block, connected to the OT
terminal by the M4 screw
BTB760-00-04-01 terminal
BAT
block, connected to the OT
terminal by the M4 screw

6.3.4 LEDs

Table 6-5 lists LEDs on the RPA2161-SI-220S54.

Table 6-5 LEDs on the RPA2161-SI-220S54

LED
RUN
ALM

6.3.5 Technical specifications

Table 6-6 lists technical specifications of the RPA2161-SI-220S54.

Table 6-6 Technical specifications of the RPA2161-SI-220S54

Dimensions
Weight
Electrical feature 1
Type
Connect the external AC
power supply.
Connect the power card
of the ISCOM6800.
Connect the battery.
Quantity
Status
2
Green
2
Red
Parameter
< 7 kg
Input
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Usage
Module working LED
Fast blinking green (4 Hz): the module is working
properly.
Slow blinking green (1 Hz): the module is working
properly while the communication fails.
Off/Green: the module is working improperly.
Alarm LED
Red: a fault is generated.
Off: no fault is generated.
43.5 mm (Height) × 442.0 mm (Width) × 249.0 mm (Depth)
(without brackets)
43.5 mm(Height) × 482.6 mm(Width) × 249.0 mm(Depth)
(without brackets)
200–240 VAC; 50/60Hz; 11 A MAX
6 Electromechanical components
Description
When being connected to the
external AC power supply, it
needs to be protected by a circuit
breaker.
When being connected with load,
it needs to be protected by a
circuit breaker.
When being connected with the
battery, it needs to be protected
by a circuit breaker.
Description
Description
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iscom6800a

Table of Contents