DYNAMIC MOTION SYSTEM - SYSTEM MANUAL // PAGE 18
The display shows "Err",
then an error number.
Code
Message
1
Firmware Error
2
Motor Over Current
3
DC Over Voltage
8
Impulse Detection Timeout
11
Speed cannot be achieved
12
Power Stage Overcurrent
13
DC Under Voltage
14
Critical DC Over Voltage
15
Strain Gauge is defective
17
Error during pairing sequence
Parameterization or firmware of
18
different Actuators in the Table
System are incompatible.
Too many / too few Actuators
19
connected
Motor short circuit and/or open
20
load
21
Firmware Error
22
Power Hub overload
23
Motor Under Voltage
Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA
NOTICE
for further information.
An internal error has occur-
red.
Disconnect the Power Hub from the Mains. Then, disconnect
System from the Power Hub. Reconnect the system again,
then operate the DM System as normal.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Perform a Position Reset Procedure (see System Manual)
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Contact LOGICDATA if the problem persists. Do not operate
the DM System if components are broken.
Disconnect the Power Hub from the Mains. Then, disconnect
System from the Power Hub. Reconnect the system again,
then operate the DM System as normal.
If this fails, perform a factory reset (see DM System Manual).
Re-paramaterize the Actuators. Contact LOGICDATA for
further information.
Connect the correct number of Actuators (as specified in
setup).
Contact LOGICDATA.
Disconnect the Power Hub from the Mains. Then, disconnect
System from the Power Hub. Reconnect the system again,
then operate the DM System as normal.
Release all Keys and wait for 5 seconds. Then, try again.
Release all Keys and wait for 5 seconds. Then, try again.
Read the table below to find the correct
response to the error code shown.
Required Actions
Need help?