Tools, Hardware, Materials; Grounding The Unit; Flooring - Monogram ZIR300NPKII Installation Instructions Manual

18” and 24”built-in column freezers 24” and 30” built-in column refrigerators
Table of Contents

Advertisement

Installation Instructions - Single Integrated Installation
REFRIGERATOR/FREEZER LOCATION
Do not install the refrigerator/freezer where the tem-
perature will go below 55°F (13°C). It will not run
often enough to maintain proper temperatures.
Do not install the refrigerator/freezer where
temperatures will go above 100°F (37°C). It will not
perform properly.
Do not install the refrigerator/freezer in a location
exposed to water (rain, etc.) or direct sunlight.
Install it on a floor strong enough to support it fully
loaded.
TOOLS AND MATERIALS REQUIRED
• Metal shears
• #1, #2 Phillips screwdriver
• Flathead screwdriver
• Putty knife
• Measuring tape
• Drill and 1/16", 5/64", 3/16", 1/2" bits
• 5/32" concrete bit (if installing anti-tip into concrete)
• 1/4", 3/8", 7/16" driver/socket
• 7/16" open wrench
• T20, T30 driver/bit
• 5/64", 1/8", 1/4" hex driver (allen wrench)
• Level
• Water shut-off valves (optional but recommended)
• 8' waterline (one per unit requiring water hookup)
• Masking tape
• Rubbing alcohol
• Adjustable wrench
• Center punch
• Heater Unification Kit (ZUGC) (only required with 4"
or less between units)
• Stainless Steel Door Kits (if applicable)
• Custom panels for doors (if applicable)
• Handle Kits (if applicable)
HARDWARE SUPPLIED (per unit)
• Water Filter Bypass Plug (if equipped)
• Air filter (if equipped)
• Anti-Tip bracket
• 3 Lag screws
• 3 Tapcon screws
• 3 Toggles with bolts
• 1 Hair Pin Cotter
• 1 Retaining pin
• Panel installation templates
• 2 Door trims
• 2 Door panel brackets
• Set screws
• #6 Phillips head wood screws
• Door Bracket Cover Top
• T30 screws
• 1 Hinge limiter pin
• Center door panel bracket
• Hi-Lo screw and square washer
31-49133-1

GROUNDING THE UNIT

WARNING
Hazard.
Failure to follow these instructions can
result in death, fire, or electrical shock.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall receptacle to minimize the
possibility of electric shock hazard from this appliance.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a standard 2-prong wall outlet is encountered, it
is your personal responsibility and obligation to have it
replaced with a properly grounded 3-prong wall outlet.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG
FROM THE POWER CORD.
DO NOT USE AN ADAPTER
PLUG TO CONNECT THE
REFRIGERATOR TO A 2-PRONG
OUTLET.
DO NOT USE AN EXTENSION
CORD WITH THIS APPLIANCE.

FLOORING

For proper installation, this product must be placed
on a level surface of hard material that is at the same
height as the rest of the flooring. This surface should
be strong enough to support a fully loaded refrigerator
or freezer, or approximately 1,200 lbs. per unit.
NOTE: Protect the finish of the flooring.
NOTE: Not recommended for installation on carpeted
flooring.
33