Design Guide - Dual Retro-Fit Installation
DUAL RETRO-FIT INSTALLATION SPACE
Dimensions in parentheses are in centimeters.
Water And Electrical Locations
Electrical and water supply must be located as shown.
For 24" Deep Cutouts
Trim Retro kits are required for a 41.5"(ZTKC42) or a
47.5" (ZTKC48) wide opening.
Heater Unification Kit ZUGC required
Product Clearances
These units are equipped with a 2-position door stop.
The factory set 115° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
For a 90° door swing, allow 4" (10.2 cm) minimum
clearance to a wall.
When installed in a corner, allow 15" (38.1 cm) for a full
115° door swing on 18" and 24" models. Allow 16.5"
(41.9 cm) on 30" models.
31-49133-1
47 1/2"
(120.7)
20"
(50.8)
6"
E
(15.2)
5"
(12.7)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16 "
5"
5"
(12.7)
(12.7)
WATER
FRONT VIEW
41 1/2"
(105.4)
18"
(45.7)
6"
E
(15.2)
5"
(12.7)
*83 1/2" min
*84 1/2" max
(212.1-214.6)
*Trim will overlap
additional 7/16 "
5"
5"
(12.7)
(12.7)
WATER
FRONT VIEW
24"
(61.0)
75"
(190.5 )
From floor
to bottom
of electrical
area
3 1/2"
(8.9)
SIDE VIEW
24"
(61.0)
75"
(190.5 )
From floor
to bottom
of electrical
area
3 1/2"
(8.9)
SIDE VIEW
Additional Specifications
• A separate 115 volt 60Hz., 15 or 20 amp power supply
is recommended for each product. An individual
properly grounded branch circuit or circuit breaker is
recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
• Water line must be located on the back wall as shown.
The water line should be 1/4" O.D. copper tubing or
QuickConnect
water line and water connection location, long enough
to extend to the front of the unit (8' [2.4m]). Installation
of an easily accessible shut-off valve in the water line
is required.
19
3/4"
(1.91)
W
3/4"
(1.91)
W
kit (WX08X10006) between the cold