Download Print this page

Ratio Electric SMART BOX Manual page 8

Dynamic charging + energy meter
Hide thumbs Also See for SMART BOX:

Advertisement

6
8
7.
Connect in-coming power to the left
terminal block.
Single Phase :
L1=Brown
N= Blue
Earth= Green/Yellow
3 Phase
L1=Brown
L2=Black
L3=Grey
N=Blue
Earth=Green/Yellow
You can change the setup by pressing the left or right arrow button.
8.
Close bottom cover and carefully slide metallized cover over the Charge Station.
After your choice has been made confirm by pressing the middle button.
2. LOAD BAL
IMPORTANT:
It is possible to connect up to 4 Smart Box modules to each other and let them
share one mains supply. Configure the Smart Box's load balancing option (LOAD
BAL) and set one module to MASTER, the others to SLAVE 1,2,3.
Make sure there is only one Master, and the Slave numbers are unique. Example:
for two units set the first module to Master and second to Slave 1.
SETUP
<- LOAD BAL ->
DISABLED – no load balancing is used
MASTER – set one of the Smart Box's to Master
SLAVE 1-3 – set the rest of the Smart Box's to Slave 1-3, when using load balancing
In the setup LOAD BAL you can choose between:
SETUP CHG MODE
<- DISABLED ->
SETUP CHG MODE
<- SLAVE 1 ->
MANUAL
You can set the charging current between 6A and 32A
(you can adjust the charging current during charging)
FIXED 16
with this option you can set the charging current to 16A
FIXED 32
with this option you can set the charging current to 32A
SMART
Load Balancing mode – the EV will charge with a
dynamic charge current, depending on Sensorbox data
and I-MAX HOME, I-MIN and I-MAX settings
OUTLET VERSION - before closing outlet cover,
be sure the outlet is unlocked!
SETUP CHG MODE
<- MASTER ->
SETUP CHG MODE
<- SLAVE 2 ->
SETUP CHG MODE
<- SLAVE 3 ->

Advertisement