ASSEMBLY & OPERATION INSTRUCTIONS
SECTION 1: MOTOR INSTALLATION AND REMOVAL
INSTALLATION - HVDP-HR
1. Locate the rubber coupling insert that was separately shipped in a plastic bag (see Figure 1).
2. Install the rubber coupling insert onto the metal coupling half located on top of the HR drive assembly.
3. Find the metal coupling half located inside the HR motor. Align this coupling with rubber insert
installed in the second step of these instructions.
4. Slide the HR motor onto the HR drive assembly.
5. Hand tighten the motor nut onto the threaded nose of the HR motor.
REMOVAL - HVDP-HR
1.
To remove the HR motor, reverse HR motor installation instructions found in this section.
INSTALLATION - HVDP-LR
1. Check the rotation direction of the LR motor (air and induction motors) before installing the motor onto the pump.
WARNING: Motor rotation must be clockwise when viewed from the fan end of the motor. Rotating the motor in the wrong direction
will cause damage to the pump.
2. Remove the motor adapter bolts (see Figure 2) and separate the motor adapter from the motor.
3. Thread the motor adapter onto the LR drive assembly. Hand tighten the motor adapter.
Note: Threads are left-handed. Also, thread lubricant is recommended to ensure smooth, bind free assembly.
4. The LR motor coupling consists of two 5/16" diameter pins welded to a hub. The LR drive assembly coupling has two slots that
receive these pins. Align the pins of the motor coupling with the slots on the drive assembly coupling and slide the motor onto
the drive assembly.
Note: Make sure the coupling is engaged properly and the motor adapter face is flush with the motor face.
5. Rotate the motor until the motor adapter mounting holes align with the threaded holes in the motor face.
6. Install the motor adapter bolts and torque to approximately 7 ft.-lbs. (9.5 N•M)
REMOVAL - HVDP-LR:
1. Remove the LR motor adapter bolts.
2. Remove the LR motor.
SECTION 2: OPERATION
1. Make sure the motor (electric or air) is properly installed on the pump tube and is in the off position. See motor instruction above
for installation instructions.
2. Insert the pump tube into the fluid to be dispensed and the hose into the container to be filled prior to starting the pump. Bung
adapters are available to provide a tighter fit between the pump tube and bung opening of a standard drum. Check drum pump
accessories at www.finishthompson.com or contact your local Finish Thompson distributor for bung adapter info.
3. Make sure the pump's discharge hose is properly secured before operating the motor.
4. Begin pumping by turning the motor on and verifying that there are no leaks. If leaks are noticed immediately turn the motor off and
check all discharge hose connections.
NEVER allow the pump to run dry.