Siemens RUGGEDCOM RSL910 Installation Manual
Siemens RUGGEDCOM RSL910 Installation Manual

Siemens RUGGEDCOM RSL910 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSL910:

Advertisement

Quick Links

RUGGEDCOM RSL910
Installation Guide
4/2019
RC1305-EN-09
Preface
Introduction
Installing the Device
Device Management
Communication Ports
Technical Specifications
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RSL910

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RSL910 Device Management Communication Ports Technical Specifications Installation Guide Certification 4/2019 RC1305-EN-09...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSL910 Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario https://www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSL910 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RSL910   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 1.3  Required Tools and Materials ......................
  • Page 6   RUGGEDCOM RSL910 Table of Contents Installation Guide 4.2  EoVDSL Ports ..........................23 4.2.1  EoVDSL Wiring ......................... 24 4.2.2  Configuration and Setup ....................25 4.2.3  EoVDSL Performance ......................25 4.3  SFP Transceivers ......................... 26 Chapter 5 Technical Specifications .................. 5.1  Power Supply Specifications ......................29 5.2  Failsafe Alarm Relay Specifications ....................30 5.3  Copper Ethernet Port Specifications ....................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSL910. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Customer Support

    RUGGEDCOM RSL910   Installation Guide Preface • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Customer Support...
  • Page 10   RUGGEDCOM RSL910 Preface Installation Guide Customer Support...
  • Page 11: Introduction

    RUGGEDCOM RSL910 to be placed in almost any location. The RUGGEDCOM RSL910 can be mounted on a DIN rail or panel for efficient use of cabinet space. The integrated power supply supports a wide range of voltages (88-300 VDC or 85-264 VAC) for worldwide operability, as well as dual-redundant, reversible polarity, 24 VDC and 48 VDC power supply inputs for high availability applications requiring dual or backup power inputs.
  • Page 12: Description

    • Terminal blocks for reliable maintenance free connections • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Section 1.2 Description The RUGGEDCOM RSL910 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Description...
  • Page 13: Required Tools And Materials

    Section 2.5, “Connecting Power” Section 5.1, “Power Supply Specifications”. Section 1.3 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RSL910: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device. Required Tools and Materials...
  • Page 14: Decommissioning And Disposal

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 15: Supported Fiber Optic Cables

    RUGGEDCOM RSL910 Chapter 1 Installation Guide Introduction Section 1.5.1 Supported Fiber Optic Cables The following fiber optic cable types are supported under the stated conditions. Distance (m) Modal Bandwidth Cable Type Wavelength (nm) (MHz·km) 100Base-FX 1000Base-SX 10GBase-SR OM1 (62.5/125) — 1300 2000 —...
  • Page 16 Chapter 1 RUGGEDCOM RSL910 Introduction Installation Guide Supported Fiber Optic Cables...
  • Page 17: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 18: Unpacking The Device

    Section 2.3 Mounting the Device The RUGGEDCOM RSL910 is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.
  • Page 19: Mounting The Device On A Din Rail

    RUGGEDCOM RSL910 Chapter 2 Installation Guide Installing the Device NOTE For detailed dimensions of the device with either DIN rail or panel hardware installed, refer to Section 5.6, “Dimension Drawings”. CONTENTS • Section 2.3.1, “Mounting the Device on a DIN Rail” •...
  • Page 20: Mounting The Device To A Panel

    Section 2.3.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSL910 can be equipped with panel adapters on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 21: Connecting The Failsafe Alarm Relay

    1. Normally Closed    2. Common    3. Normally Open Section 2.5 Connecting Power The RUGGEDCOM RSL910 supports power input from a single high AC/DC or low DC power supply. IMPORTANT! • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
  • Page 22: Connecting High Ac/Dc Power

    Installation Guide IMPORTANT! Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated. Use the following specifications as a guide for VDSL external surge protection: •...
  • Page 23 RUGGEDCOM RSL910 Chapter 2 Installation Guide Installing the Device Figure 6: Terminal Block Wiring 1. Positive/Live (+/L) Terminal    2. Negative/Neutral (-/N) Terminal    3. Surge Ground Terminal    4. Braided Ground Cable Connecting High AC/DC Power...
  • Page 24: Connecting Low Dc Power

    Section 2.5.2 Connecting Low DC Power RUGGEDCOM RSL910's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply. To connect a low DC power supply to the device, do the following: NOTE Torque all terminal connections to 0.6 N·m (5 lbf-in).
  • Page 25 RUGGEDCOM RSL910 Chapter 2 Installation Guide Installing the Device ± ± Figure 8: Terminal Block Wiring – Single DC Power Supply Inputs 1. Positive Terminal    2. Negative Terminal    3. Surge Ground Terminal    4. Braided Ground Cable Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 26 Chapter 2 RUGGEDCOM RSL910 Installing the Device Installation Guide ± ± ± ± Figure 9: Terminal Block Wiring – Dual DC Power Supply Inputs 1. Positive Terminal    2. Negative Terminal    3. Surge Ground Terminal    4. Braided Ground Cable Using a braided wire or other appropriate grounding wire, connect the surge ground terminal to the chassis ground connection.
  • Page 27: Device Management

    Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM ROS console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS User Guide for the RUGGEDCOM RSL910. IMPORTANT! Ethernet cables should be only be connected/disconnected in a non-hazardous area, or when the device is not energized.
  • Page 28 Chapter 3 RUGGEDCOM RSL910 Device Management Installation Guide Figure 10: Console Ports 1. USB Type-B Console Port    2. Serial DB9 Console Port Use the following settings to connect to either port: Speed 57600 baud Data Bits Stop Bit Parity None Flow Control Terminal ID VT100 The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector.
  • Page 29: Configuring The Device

    RUGGEDCOM RSL910 Chapter 3 Installation Guide Device Management Name Description Reserved (Do Not Connect) Connected internally. Connected internally. Ethernet Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM ROS console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RSL910 is https://192.168.0.1.
  • Page 30 Chapter 3 RUGGEDCOM RSL910 Device Management Installation Guide Configuring the Device...
  • Page 31: Communication Ports

    Chapter 4 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSL910 can be equipped with various types of communication ports to enhance its abilities and performance. Figure 12: Port Assignment 1. Ports 7 and 8    2. Ports 1 to 6    3. Port 9 and 10...
  • Page 32: Copper Ethernet Ports

    Installation Guide Section 4.1 Copper Ethernet Ports The RUGGEDCOM RSL910 supports multiple 10/100Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) shielded or unshielded twisted-pair cables with RJ45 male connectors. WARNING! Electric shock hazard – risk of serious personal injury and/or equipment interference. When shielded cables are used, make sure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end.
  • Page 33: Eovdsl Ports

    Section 4.2 EoVDSL Ports The RUGGEDCOM RSL910 features a pluggable terminal block that supports up to two Universal EoVDSL connections. Universal EoVDSL connections are Master/Slave selectable and offer symmetric data rates up to 140 Mbps (with a VDSL link data rate up to 100 Mbps) or distances up to 3 km (1.8 mi).
  • Page 34: Eovdsl Wiring

    Chapter 4 RUGGEDCOM RSL910 Communication Ports Installation Guide Terminal Description Receive on Port 9 Transmit from Port 9 Receive on Port 10 Transmit from Port 10 Figure 15: EoVDSL Terminal Block CONTENTS • Section 4.2.1, “EoVDSL Wiring” • Section 4.2.2, “Configuration and Setup” •...
  • Page 35: Configuration And Setup

    Section 4.2.2 Configuration and Setup If the RUGGEDCOM RSL910 and another device both have Universal EoVDSL ports, configure one device to be the Master and the other the Slave. Once configured and connected together, each device will attempt to achieve the maximum speed based on the line length and conditions.
  • Page 36: Sfp Transceivers

    0.2/0.2 Section 4.3 SFP Transceivers The RUGGEDCOM RSL910 supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state.
  • Page 37 RUGGEDCOM RSL910 Chapter 4 Installation Guide Communication Ports Compatible SFP Transceivers For more information about which SFP transceivers are compatible with the RUGGEDCOM RSL910, as well as instructions for ordering and installation/removal, refer to the RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309].
  • Page 38 Chapter 4 RUGGEDCOM RSL910 Communication Ports Installation Guide SFP Transceivers...
  • Page 39: Technical Specifications

    RUGGEDCOM RSL910 Chapter 5 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 5.1, “Power Supply Specifications” • Section 5.2, “Failsafe Alarm Relay Specifications” • Section 5.3, “Copper Ethernet Port Specifications” • Section 5.4, “Operating Environment”...
  • Page 40: Failsafe Alarm Relay Specifications

    Chapter 5 RUGGEDCOM RSL910 Technical Specifications Installation Guide Non-Hazardous Environments Input Voltage Internal Maximum Power Power Supply Type Isolation Fuse Rating Consumption Minimum Maximum 88 VDC 300 VDC 3.15 A(T) 4 kVAC 12 W 85 VAC 264 VAC 3.15 A(T) 5.5 kVDC...
  • Page 41: Operating Environment

    Typical distance. Dependent on the number of connectors and splices. RMS 1 minute. Section 5.4 Operating Environment The RUGGEDCOM RSL910 is rated to operate under the following environmental conditions. Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
  • Page 42 Chapter 5 RUGGEDCOM RSL910 Technical Specifications Installation Guide 124.7 65.1 116.6 Figure 16: Overall Dimensions Dimension Drawings...
  • Page 43 RUGGEDCOM RSL910 Chapter 5 Installation Guide Technical Specifications 78.8 120.6 13.7 101.6 ø 8.1 ø 4.0 ø 4.0 57.2 Figure 17: Panel Mount Dimensions Dimension Drawings...
  • Page 44 Chapter 5 RUGGEDCOM RSL910 Technical Specifications Installation Guide 126.2 134.3 Figure 18: DIN Rail Mount Dimensions Dimension Drawings...
  • Page 45: Certification

    RUGGEDCOM RSL910 Chapter 6 Installation Guide Certification Certification The RUGGEDCOM RSL910 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. CONTENTS • Section 6.1, “Approvals” • Section 6.2, “EMC and Environmental Type Tests”...
  • Page 46: European Union (Eu)

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens”.
  • Page 47: Ised

    Chapter 6 Installation Guide Certification Section 6.1.5 ISED This device is declared by Siemens Canada Ltd to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) Section 6.1.6 TÜV SÜD This device is certified by TÜV SÜD to meet the requirements of the following standards: •...
  • Page 48: Emc And Environmental Type Tests

    Chapter 6 RUGGEDCOM RSL910 Certification Installation Guide Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSL910 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests Test Description Test Levels Severity Levels IEC 61000-4-2 Enclosure Contact ± 6 kV Enclosure Air ±...

Table of Contents