Vertiv Liebert EXS User Manual

Vertiv Liebert EXS User Manual

60kva ups
Hide thumbs Also See for Liebert EXS:
Table of Contents

Advertisement

Liebert® EXS
TM
60kVA UPS User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Liebert EXS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vertiv Liebert EXS

  • Page 1 Liebert® EXS 60kVA UPS User Manual...
  • Page 3 Customer service hotline: 1800 209 6070 • Asia Australia - au.service@vertiv.com New Zealand - au.service@vertiv.com Philippines - ph.service@vertiv.com Singapore - sg.service@vertiv.com Malaysia - my.service@vertiv.com For Technical Support, users may contact the nearest Vertiv Co. local sales office or service center. BOM: 31013796...
  • Page 6        ...
  • Page 7   ...
  • Page 9      ...
  • Page 10 VIII...
  • Page 11 TABLE OF CONTENTS 1 Product Introduction ................1 ..............Mechanical Installation 3 Electrical Installation ................24...
  • Page 12 4 Operator Control and Display Panel ............31 5 UPS Operating Instructions ..............50...
  • Page 13 6 Parallel System and LBS System ............69 7 Communication ..................81...
  • Page 14 8 Maintenance ..................90 9 Options ....................93 10 Specifications ..................99 Appendix 1 LCD Parameters Setting............ 99 Appendix 2 Glossary ................99 Appendix 3 Hazardous Substances and Content ......99...
  • Page 15 ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫...
  • Page 16 输出继电器 整流器 逆变器 市电输入 UPS输出 主路输入开关Q1 电池 电池充电器 ⚫ ⚫ Output Input Maintenance bypass switch Maintenance bypass Static switch Bypass automatic switch Bypass input Bypass input switch Rectifier Inverter Inverter switch Mains input UPS output Rectifier input switch Output switch Battery Battery charger...
  • Page 19 ⚫ ⚫ ⚫...
  • Page 20 ⚫...
  • Page 21 ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫...
  • Page 22 Rectifier Inverter Inverter switch Mains input UPS output Output switch Rectifier input switch Battery Battery charger...
  • Page 23 Maintenance bypass switch Maintenance bypass UPS output Bypass input...
  • Page 32 Packing belt Protective cardboard (4 PCS)
  • Page 33 Front panel of the battery compartment Front view Fixed part...
  • Page 34 Wall 墙壁 >200mm 500mm Cabinet 机柜 200mm...
  • Page 37 Front view Left view outlet inlet Top view (door open)
  • Page 44 BAT+ (Red) BAT N (Blue) BAT- (Black) Step 1: Dismantle the cover board at top right side of the cabinet rear, then you can see the wiring channel. Rear view Step 2: Lead the connected signal cables out through the wiring channel shown in Front view step 1.
  • Page 46 Settings Control Status About Maintain...
  • Page 50 Input Bypass Battery Output L-N voltage(V) 220.0 220.2 220.8 Frequency(Hz) 50.00 50.00 50.00 L-L voltage(V) 381.2 381.9 381.7 Input Bypass Battery Output Battery status Float Battery voltage(V) 270.5 283.2 Battery current(A) 0.67 0.86 Backup time(Minut... Remaining capacit... 95.7 Input Bypass Battery Output L-N voltage(V)
  • Page 51 Settings Control Status About Maintain...
  • Page 52 Settings Control Status About Maintain...
  • Page 53 Settings Control Status About Maintain Current History 00 Load on Inverter 01-12-2018 13:48:09 00 Inverter Manual On 01-12-2018 13:47:10 00 Fault Clear 01-12-2018 13:46:53 01 No Battery 01-12-2018 13:43:05 1/ 1...
  • Page 54 Status Settings Control About Maintain Product Run time Efficiency Product type 380V-50Hz-EXS Serial number 1230000000000... Monitor APP version V000B012D000 Monitor Bootloader... V000B003D000 Monitor Resource ve... V000B007D000 1# Rectifier DSP ve... V000B009D000 1# Inverter DSP ver... V000B010D000...
  • Page 55 Settings Control Status About Maintain...
  • Page 58 ℃ ℃...
  • Page 66 218.2V 8.2V 50.0Hz Charge 563.8V 219.3V 50.0Hz 200.0 Min...
  • Page 67 Settings Control Status About Maintain Confirm 218.2V 8.2V 充电 50.0Hz Turn on local INV? 563.8V 220.0V 49.9Hz 200.0分 219.0V 220.4V 49.9Hz 49.9Hz Charge 81.1% 553.9V 220.2V 49.9Hz 11.0 Min...
  • Page 69 Confirm 217.8V 220.2V This operation leads 49.9Hz 49.9Hz to output shutdown 2.1V...
  • Page 70 Confirm 217.7V 219.8V 充电 49.9Hz 49.9Hz Turn on local INV? 553.9V 219.5V 49.9Hz 11.0分 Confirm 217.7V 219.8V 充电 49.9Hz 49.9Hz Transfer with interrupt 553.9V 219.5V 49.9Hz 11.0分...
  • Page 72 ⚫ ⚫ ⚫ ⚫ ⚫ ⚫ ⚫...
  • Page 75 Settings Control Status About Maintain...
  • Page 77 Monitor System Language English Date format M/D/Y Date 01-12-2018 13:55:33 Time Audible alarm Enable Serial 1 baudrate 9600 bps Serial 2 baudrate 9600 bps Monitor System Language English Date format M/D/Y Date 01-12-2018 Time 13:55:33 Audible alarm Enable Serial 1 baudrate 9600 bps Serial 2 baudrate 9600 bps...
  • Page 78 System Monitor Language English Date format M/D/Y Date 01-12-2018 Time 13:55:33 Audible alarm Enable Serial 1 baudrate 9600 bps Serial 2 baudrate 9600 bps Monitor System Monitor System Language English Language English Date format M/D/Y Date format M/D/Y Date 01-12-2018 Date 01-12-2018 Time...
  • Page 79 Monitor System Monitor System Language English Language English Date format M/D/Y Date format M/D/Y Date 01-12-2018 Date 01-12-2018 13:55:33 Time 13:55:33 Time Audible alarm Enable Audible alarm Enable Serial 1 baudrate 9600 bps Serial 1 baudrate 9600 bps Serial 2 baudrate 9600 bps Serial 2 baudrate 9600 bps...
  • Page 80 Monitor System Input UPS address Card slot protocol YDN23 Password for settings Change settings password 0***** Monitor System Language English Date format M/D/Y Date 01-12-2018 13:55:33 Time Audible alarm Enable Serial 1 baudrate 9600 bps Serial 2 baudrate 9600 bps Monitor System UPS address...
  • Page 81 Monitor System Input UPS address Card slot protocol YDN23 Password for settings Change settings password 0***** Monitor System Input UPS address Card slot protocol YDN23 Input new password Change settings password 0***** Monitor System Input UPS address Card slot protocol YDN23 Confirm new password Change settings password...
  • Page 82 Monitor System Notify UPS address Card slot protocol YDN23 Password changed OK! Change settings password 0*****...
  • Page 84 External Input power bypass switch supply Mains input Mains input L1,L2,L3,N L1,L2,L3,N UPS 1 UPS 2 Rectifier Rectifier Charger Charger Bypass Bypass Static Static automatic automatic switch switch switch switch Inverter Inverter Battery 1 Battery 2 L1, L2,L3,N L1, L2,L3,N Output distribution To load Note: Q1, Q2 and Q5 are optional while Q3 is standard...
  • Page 86 UPS 2 UPS 2 J2 2.3 Bypass module J14 14.6 J3 3.3 Communication J2 2.4 board J14 14.8 J3 3.4 J14 14.6 J2 2.3 J3 3.3 J14 14.8 J3 3.4 J2 2.4 Communication Bypass module board UPS 1 UPS1 UPS 2 UPS 2 J3 3.1 Bypass module...
  • Page 92 Bypass Bypass Rectifier Rectifier Q2 Q3 Q2 Q3 To load Note: Q1, Q2 and Q5 are optional while Q3 is standard...
  • Page 93 Bypass Bypass Rectifier Rectifier Rectifier Rectifier UPS 1 UPS 4 UPS 1 UPS 4 Q2 Q3 Q2 Q3 Q2 Q3 Q2 Q3 Parallel Parallel cable cable To load Note: Q1, Q2 and Q5 are optional while Q3 is standard PARALLEL1 PARALLEL2 PARALLEL1 PARALLEL2 UPS1 UPS2...
  • Page 98 PARALLEL 1 PARALLEL 2 CAN2 2 4 6 8 10 12 14 16 2 4 6 8 1 3 5 7 1 2 3 4 7 9 11 13 15 RS485 MONITOR PARAMSET...
  • Page 104 ⚫ ⚫ ⚫...
  • Page 110 ( )...
  • Page 116 Русский...
  • Page 118 ( ) ( ) ( ) ( ) ( ) ( ) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 120 Vertiv.com | Asia-Pacific © 2019 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co.

Table of Contents

Save PDF