Minimum Clearance Requirements

WARNING
FIRE HAZARD:
• Do not install Ultra-Glo strip heaters above or
around combustible surfaces. Discoloration
or combustion could occur. Ultra-Glo strip
heaters must be installed in non-combustible
surroundings only.
Models
(A)
UGA and
14"
UGAL
(356 mm)
UGAH and
17"
UGAHL
(432 mm)
Pass-Through Shelf
C
Counter
Figure 7. Clearance Requirements
Form No. UGAM-0908
All manuals and user guides at all-guides.com
(B)
(C)
3"
1"
(76 mm)
(25 mm)
3"
1"
(76 mm)
(25 mm)
B
A

Recommended Mounting Heights

Standard Wattage
Height
14"–18"
(356–457 mm)
Figure 8. Recommended Mounting Height for all
UGA single element depth models.
19-1/2" (495 mm)
Standard
Wattage
Height
18"–22"
(457–559 mm)
21" (533 mm)
Figure 9. Recommended Mounting Height for all UGA
dual element depth models with a 3" (76 mm) spacer.
22-1/2" (572 mm)
Standard
Wattage
Height
18"–22"
(457–559 mm)
24" (610 mm)
Figure 10. Recommended Mounting Height for all UGA
dual element depth models with a 6" (152 mm) spacer.
13
INSTALLATION
Add 3" for
10.5"
units with lights.
(267 mm)
High Wattage
Height
16"–22"
(406–559 mm)
15" (381 mm)
High
Wattage
Height
22"–26"
(559–660 mm)
High
Wattage
Height
22"–26"
(559–660 mm)