Installation; General - Hatco GLO-RAY GR Series Installation And Operating Manual

Infrared strip heaters
Table of Contents

Advertisement

General

Use the information in this section to prepare for
installation of the strip heater. Make sure to locate
the specific information for the model of strip heater
and type of installation.
WARNING
FIRE HAZARD:
• Locate the unit the correct distance from
combustible walls and materials. If safe
distances are not maintained, discoloration
or combustion could occur. Refer to specific
installation and mounting information in this
manual for proper clearances.
• Make
sure
to
follow
information listed below for specific strip
heaters. If safe distances are not maintained,
discoloration or combustion could occur.
a. Do not install standard wattage strip
heaters (GR, GRA, GRN, GRAL Series) less
than 10" (254 mm) above combustible
surfaces.
b. Do not install high wattage strip heaters
(GRH, GRAH, GRNH, GRAHL Series) less
than 13-1/2" (343 mm) above combustible
surfaces.
c. Do not install dual strip heaters (GRA-XXD,
GRAH-XXD, GRAL-XXD, and GRAHL-XXD
Series) above combustible surfaces.
e. Install all single strip heaters with a
minimum distance of 3" (76 mm) from a
combustible wall or adjacent surface.
CAUTION
To ensure safe and proper operation, refer to the
Clearance Requirements listed in the Installation
section of this manual.
NOTICE
Heat damage to countertop material such as
Corian
®
and similar products (other than
stainless steel) is not covered under the Hatco
warranty. Contact the manufacturer of the base
material for temperature limits and application
information before installing the unit.
To prevent unit failure from excessive heat, do
not add a decorative soffit to hide a pass-
through mounted strip heater.
NOTE: Contact the countertop manufacturer of the
base material for application information
and surface temperature limits before
installing the unit.
Form No. GRM-0508
All manuals and user guides at all-guides.com
the

installation

1. Remove the unit from the shipping carton and
remove all packing materials.
2. Remove the information packet.
NOTE: To prevent delay in obtaining warranty
coverage, fill out and mail in the warranty
card to Hatco.
NOTE: If unit is equipped with optional equipment,
see the ACCESSORIES section near the
back of this manual.
Dual Mounting
When mounting units side-by-side, a space not less
than 3" (76 mm) must be maintained between units.
Dual units ordered from the factory are shipped with
a pre-assembled 3" (76 mm) or 6" (152 mm) spacer.
NOTE: Dual units are available with aluminum
housings only.
Installation of two or more separate units with
less than 3" (76 mm) between housings may
result in premature failure of component parts.
Failure to provide proper spacing may result in
heat damage to electrical components.
Under Shelf Mounting
When mounting a unit under a shelf, use adjustable
angle brackets to assure proper spacing. Remote
control enclosures are recommended to keep
switches out of the heat zone and prevent
premature failure.
Pass-Through
If pass-through area is 12" to 16" (305 to 406 mm)
deep, the standard wattage or high wattage single
unit can be used. For a 20" to 24" (508 to 610 mm)
deep pass-through area, a dual unit in either
standard or high wattage is recommended.
Installation of multiple units must have a minimum
spacing of 3" (76 mm) between heaters.
T-Legs or C-Legs
Do not mount units longer than 60" (1524 mm)
on T-legs or C-legs.
Over Steam Table
When mounting over a steam table, a remote
control switch enclosure must be installed.
11
INSTALLATION
NOTICE

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glo-ray grh seriesGlo-ray gra seriesGlo-ray grah seriesGlo-ray gral seriesGlo-ray grahl seriesGlo-ray grn series ... Show all

Table of Contents