Permanent Surface Mount

Tubular stand mounting permanently attaches the
unit to a countertop or serving table. All wiring may
be concealed within one of the tubular stands.
CAUTION
To ensure safe and proper operation, refer to the
Clearance Requirements listed in the Installation
section of this manual.
Tubular stands are available in aluminum non-
adjustable heights from 10"-16" (254-406 mm) or in
stainless steel adjustable heights from 10"-14" (254-
356 mm).
NOTE: Tubular stands are not field retrofittable.
NOTE: If wiring is to be concealed, a 1" (25 mm)
diameter hole must be provided in the
mounting surface centered under the stand
containing the wiring conduit.
Non-Adjustable Stand
1-3/16"
(30 mm)
Distance from end of unit to center of conduit hole.
Needed for 1" diameter hole cutout in mounting surface.
Figure 19. Countertop Conduit Hole Dimension
1. Position the unit upside-down on a flat surface.
NOTE: Units for this application are supplied with
the conduit attached to one side of the unit.
Conduit should not be removed.
2. If applicable, route the flexible conduit through
the center of one of the stands (see Figure 20.)
3. Pull the conduit-side stand up against the unit
and secure the stand to the unit using the
screws supplied. Align the the other stand with
the mounting holes at the other end of the unit
and secure the stand to the unit using the
screws supplied.
4. If applicable, route the flexible conduit through
the 1" diameter hole cut into the mounting
surface.
5. Secure the stands to the mounting surface.
Form No. GRM-0508
All manuals and user guides at all-guides.com
Adjustable Stand
1-1/16"
(27 mm)
NOTE: The adjustable stands can be raised or
lowered by turning the locking set screw
counterclockwise one turn with an Allen
wrench, and then raising or lowering the
unit to the desired height and retightening
the screw. Do not loosen the screw more
than necessary.
NOTE: Two pairs of stands will be needed for
mounting dual units.
Set
Screw
Mounting
Screw
Adjustable
Stand
Figure 20. Tubular Stand Mounting
15
INSTALLATION
Non-Adjustable
Stand
Flexible
Conduit

Hide quick links: