3. Wiring the Power Inputs
The Upper Panel of the
socket and consists of one terminal block connector within 6 contacts. Please follow
the steps below to insert the power wire.
1. Insert positive/negative DC power wires into Contacts 1 and 2 for Power 1, or
Contacts 5 and 6 for Power 2.
IGS-6325-16P4S: DC 48-56V
IGS-6325-8T4X/IGS-6325-8T8S4X: 12~48V DC, 24V AC
Figure 3-2: IGS-6325-8T4X/IGS-6325-8T8S4X Upper Panel
Industrial Managed
DI 0 DI 1 DO 0 DO 1 GND GND
1 2 3 4 5 6
1 2 3 4 5 6
V1+
1A@24V
DC1
Input: 48-56V
Dual power input is required
for maximum PoE loading.
Refer to user's manual for
more details.
Figure 3-1: IGS-6325-16P4S Upper Panel
DI0
DI1 DO0 DO1
GND
1 2 3 4 5 6
1A@24V
1 2 3 4 5 6
Switch indicates a DC inlet power
V2+
DC2
, 7.5A max.
GND