Installing of the chimney and fixing of the hood
When the hood is installed in recycling version the chimney
has to be positioned with the slots upwards. When the hood
is installed in ducting version it has to be positioned in the
opposite way.
• Place the chimney on the frame and fix it to the upper
part of it with the earlier removed screws. When install-
ing the hood in recycling version make sure that the slots
correspond to the air outlet of the recycling air outlet
piece 15.
• Open the lighting unit by slightly pulling the notch. Re-
move the unit from the hood by sliding the fixing pivot.
• Remove the filter pushing it towards the back side of the
hood unit and simultaneously pulling downwards.
• Remove possible charcoal filters.
• In order to fix the hood body to the frame insert the 4
screws 12f in their seats. It is necessary to leave at least
4-5 mm gap between the screw heads and the frame plate.
• Hook the hood canopy to the frame and turn it to the left
until it reaches the stop, then lock the screws immediately
to prevent the hood canopy from falling out accidentally.
ELECTRICAL CONNECTION
• Connect the Hood to the mains power supply, inserting a
two-pole cut-out switch with contact aperture of at least 3
mm along the line.
• Ensure that the supply cable connector is properly in-
serted into the Suction device socket
• Hook up the Commands connector Cmd.
• Hook up the Spotlights connector Lux to the socket pro-
vided behind the lighting unit cover.
• For the Recirculation Version, fit the Activated Charcoal
Odour Filter.
• Replace the filters and the lighting unit.
EN