10. Unplug the gear motor (three connectors) (Fig. 16).
11. Remove ground screw connection.
12. Remove gear motor:
§ Remove M6 allen screw, retainer, spacer and key (Fig. 18.1).
§ Remove two M6x90 allen screws (Fig. 18.2).
§ Pull gear motor from auger (Fig. 18.3).
§ Remove main housing insulation (Fig. 18.4).
13. Remove all traces of Petrol-gel from auger shaft.
14. Remove compression nozzle:
§ Loosen hose clamp (Fig. 19.1).
§ Remove transport tube (Fig. 19.2).
Fig. 17
Fig. 18
Fig. 19
Dispenser and Ice Machine 230 V/50 Hz and 220 V/60 Hz
2
3
1
2
1
2
4
17