Undetermined Problems - IBM Aptiva 2124 Hardware Maintenance Service

Service level a
Table of Contents

Advertisement

Undetermined Problems

If an error code is present, go to "Index of Symptoms, Messages, Error
Codes, or Beeps" on page 2-8. If no error code is present, continue with this
check. Check the power supply voltages (see "Power Supply Cable
Connector Specifications" on page 5-15). If the voltages are correct, return
here and continue with the following steps:
1. Power off the system unit.
2. Perform the following checks, one by one, until you have isolated the
problem FRU (refer to "Parts/Test Point Locations" on page 5-1 for
locations):
Load default settings in setup.
Check all system board jumper positions and switch settings.
Check all adapter card jumper positions.
Check all device jumper positions.
Check all cables and connectors for proper installation.
If the jumpers, switch, and voltage settings are correct, return here and
continue:
3.
Remove or disconnect the following, one at a time:
Non-IBM devices
External devices
Any adapters
Modem card, if installed
CD-ROM drive
Diskette drive
Hard disk drive
DIMM
Processor
System board
4. Power on the system unit.
5. Repeat steps 1 through 4 until you find the failing device or adapter.
6. If software related, reload software from Recovery CD.
2-42