5.2 Preparing the installation

It is recommended to install the control unit at a height of at least 1m60 above the ground and out of the reach of children.
Be careful not to obstruct the back plate. Leave a 20cm space on sides and a 50cm space above and below the unit to ensure
a proper and necessary ventilation.
In hot season, the aluminium base can reach temperatures of 60°C. Remove any material that may be damaged by the heat
released by the base.

5.3 Installing and connecting the control unit

Position the drill holes using the template on the front of the box.
Affix the control unit using the fixation kit provided.

5.4 Electrical connections

Warning : All electrical wiring and connection work must be carried out by a professional electrician. The corresponding
invoice must be attached to any claims made under guarantee. All installations must be equipped with a 30mA (max)
differential circuit breaker positioned upstream from the chlorinator's control unit. Disconnect the power supply
before proceeding with any installation or maintenance operations. The chlorinator must be connected with two
slaving systems : a hydraulic slaving system (for the flow switch) and an electric slaving system (230Vac slaved to the
filtration process).

5.4.1 Protection by circuit breaker

The chlorinator's power supply must be connected to the building's electric power supply network. It must be protected by
a 4A magnetothermal two-pole circuit breaker (phase + neutral). This protection device must be dedicated to the
chlorinator only.
As this is a Class I device, it must be grounded. This is compulsory.

5.4.2 Slaved electric power supply

The chlorinator must be powered up only when the filtration is in operation. The 230Vac electric power supply must be
monitored either by a contact available on the filtration contactor or by a specially dedicated contactor whose coil is wired
up in parallel to the filtration contactor.

5.4.3 Cables dimensions

For the chlorinator power supply, the cross section of the cables must be between 0,75mm² and 2,5mm², the total cross
section of the power cable must be between 6mm² et 10mm².