Connection Of The Chlorinator's Control Unit - AQUALUX 103646 Installation And Care Instruction

Salt chlorinator
Table of Contents

Advertisement

Available languages

Available languages

5.4.4 Connection of the chlorinator's control unit

The unit is equipped with
2 (PE) cable glands on top of the unit.
- The one on the left is dedicated to the cell's power cable
- The one on the right is dedicated to the 230Vac mains supply power cable.
1 yellow female plug CINCH type on the opening part.
This plug must be connected to the yellow male plug of the connection cord to the possible automatic cover unit.
The cord is equipped on one side with a yellow CINCH type male plug (to be connected to the unit) and with a connection
unit on the other side.
- Open contact or unplugged connector (in that case, place the anti oxydation lid over the female plug), the chlorinator
considers that the pool is uncovered or not equipped with an automatic cover.
- Closed contact, the chlorinator considers that the pool is covered.
If the pool is equipped with an automatic cover, connect the 2 terminals of the connection unit to the contact of the
automatic cover's unit (see above picture).
- Terminal C and terminal R for the UNICUM gearmotor unit (type PL3210, PL6010, DL3010, DL6010)
- Terminal 8 (NO) and terminal 9 (C) for the immersed SIREM gearmotor unit.
For other gearmotor units brands/models, please contact the manufacturer.
Wiring of the cell :
Successively position terminal blocks, spring washers and then nuts. Terminal blocks can be mounted indifferently on either
one or the other terminal.
Gently block the upper nut so as to avoid creating an irreversible leakage at the connections' level.
NOTESAQX FRGBIT - IND B - 02/2012
Connection to the automatic cover unit
18 / 36

Advertisement

Table of Contents
loading

This manual is also suitable for:

103647

Table of Contents