About This Document; General Safety Precautions; Electrical Connection - STEINEL DALI-2 IR 180 Manual

Application controller
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 12
GB
1� About this document
Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or in part only with our
consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
Disconnect the power supply before attempting any
!
work on the unit�
• During installation, the electric power cable to be connected must not be
live. Therefore, switch off the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor involves work on the mains power supply. This work
must therefore be carried out professionally in accordance with national
wiring regulations and electrical operating conditions.
• Only use genuine replacement parts.
• Repairs must only be made by specialist workshops.
I II
III
• Note
: The cable of the external switch (S) is not intended for use as a
neutral conductor connection for loads. (Fig� 4�4 / 4�5)
3� IR / HF 180
Proper use
– Sensor switch suitable for indoor wall-mounting.
– Intelligent sensor technology automatically switches DALI lights ON when
the room is entered.
IR 180
The IR 180 is equipped with a pyro sensor which detects the invisible heat
emitted by moving objects (people, animals etc.). The heat detected in this
way is converted electronically into a signal that switches a connected load ON
(e.g. a light). Heat is not detected through obstacles, such as walls or panes of
glass. Heat radiation of this type will, therefore, not trigger the sensor.
- 22 -
HF 180
The HF 180 is an active motion detector. It responds to the slightest movement
regardless of temperature. The integrated HF sensor emits high-frequency
electromagnetic waves (5.8 GHz) and receives their echo. In response to the
slightest movement in the detection zone, the change in echo is perceived by
the sensor. A microprocessor then issues the switch command "switch light
ON". Movement can be detected through doors, panes of glass or thin walls.
Optionally, all function settings can be made via the RC5, RC8 remote controls
as well as the Smart Remote. (➜ "8� Accessories")
Package contents for IR 180 (Fig� 3�1)
Package contents for HF 180 (Fig� 3�2)
Product dimensions for IR 180 / HF 180 (Fig� 3�3)
Product components (Fig� 3�4)
A Rocker switch
B Cover
C IR 180 lens / HF 180 cover
D Removal slot
E Sensor module
F Status LED
G Surround
H Metal frame
I
Load module
4� Electrical connection
• Switch OFF power supply (Fig� 4�1)
Wiring up the sensor switch: Under section 6 of VDE 0100520, a multi-core
lead containing both the mains voltage leads as well as the control leads (e.g.
NYM 5 × 1.5 mm
). may be used for the wiring between sensor and electronic
2
ballast.
The mains connection terminal is designed for a maximum of 2 × 2.5 mm².
The mains power supply lead is a cable with at least 4 conductors:
L
= phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (usually green/yellow)
S = Connection for an external switch
DA1–, DA1+, DA2–, DA2+ = Connection to the DALI BUS
P = For connecting several presence detectors
I II
Note
III P conductor:
The cable between two sensors must be no more than 50 m in length.
No more than 25 m to each further sensor. No more than 300 m in total
when installing 10 sensors.
- 23 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dali-2 hf 180

Table of Contents