SET VALUE
DESCRIPTION
It sets re-discharge time.
Within [splice mode edition], it
automatically sets to discharge the re-
Re-Discharge Time
discharge amount with the same intensity
as that of [discharge amount 2]. If
[discharge amount 2] is set as ON/OFF,
re-discharge is automatically changed.
When optical fiber is made thin, splice loss
is sometimes increased. This pulling
Pulling Splice
function is set as "OFF." The following 3
parameters decide the pulling shape.
It designates time period from the last of
Pulling Standby
optical fiber advance amount to the
beginning of pulling.
Pulling Speed
It sets optical fiber's pulling speed.
Pulling Length
It sets optical fiber's pulling time.
It is the sum of initially measured splice loss
value and the increased loss. When splicing
a special optical fiber or other optical fibers,
high loss may be incurred in spite of the
Minimum loss
optimum discharge conditions. To match
the estimated splice loss and the actual
splice loss, the minimum value of actual
splice loss should be set.
MFD Left
Mode field diameter Left
MFD Right
Mode field diameter Right
58 | SWIFT K33A ALL IN ONE FUSION SPLICER
SLEEVE HEATER SETTINGS & ADJUSTMENTS
Heater settings are pre-programmed in the K33A for industry standard shrink sleeve sizes
GENERAL
USER
and Splice on Connectors (SOC's). Users can select a setting, Edit the parameters of a
MODE
MODE
setting, create a new setting, replace a setting or delete a setting. The settings determine
which area of the heater is activated so it is important to have the setting correctly set to
avoid damage to the fiber, splice or connector.
NOTE:
System default heater settings 1-40 cannot be deleted.
Editable
PRESET HEATER SETTINGS & DESCRIPTIONS
SET VALUE
60mm
60mm IS-60
45mm IS-45
40mm
Editable
S09
S09-C
Non-
Editable
S20
S30
S30-C
LC09/20-C
ST09-C
ST30-C
Be sure to choose the correct mode for each sleeve tube type and SOC otherwise sleeve
tubes may not shrink properly of the fiber can be damaged.
NOTE:
For the SOC's the settings are defaulted for the use of Swift brand splice on connectors.
Other Brands of sleeve tubes may not shrink properly.
DESCRIPTION
Standard 60mm micro sleeve
60mm micro sleeve
45mm micro sleeve
Standard 40mm micro sleeve
45mm sleeve
22mm sleeve for SOC(SC-0.9mm)
45mm sleeve for2.0mm optical cable
45mm sleeve for3.0mm optical cable
32mm sleeve for SOC(SC-3.0mm)
25mm sleeve for SOC(LC-0.9 and 2.0mm)
28mm sleeve for SOC(ST-0.9mm)
36mm sleeve for SOC(ST-3.0mm)
OTHERS
Sleeve type,
mode title
1 and mode
title 2 cannot
be edited.
americanilsintech.com | 59