K33A MENU SETTINGS
There are 9 sub menus in the main menu. To display the main menu, press
There are 9 sub menus in the main menu. To display the main menu, press
on the K33A or on the touch screen. The display will appear per the picture below.
SPLICE
DEL:
delete a preset splice mode
REPLACE:
select a splice mode from the database and replace it.
NEW:
create a new custom mode to be added to the list of existing splice modes
EDIT:
edit the specifi c splice parameters (i.e. temperature-time etc.)
SELECT:
select a splice mode for the current operation.
CANCEL:
close menu window.
HEATER
DEL:
delete a preset splice mode
REPLACE:
select a splice mode from the database and replace it.
NEW:
create a new custom mode to be added to the list of existing splice modes
EDIT:
edit the specifi c splice parameters (i.e. temperature-time etc.)
SELECT:
select a splice mode for the current operation.
CANCEL:
close menu window.
44 | SWIFT K33A ALL IN ONE FUSION SPLICER
AUTO STRIPPER
either
either
DEL:
delete and existing Stripper mode.
REPLACE:
select a Stripper mode from database replace it.
NEW:
Create a new custom mode to be added to the existing stripper modes
EDIT:
edit the specifi c parameters of an existing Stripper mode (i.e. heat-time etc.)
SELECT:
select a Stripper mode for the current operation.
CANCEL:
close menu window.
HISTORY
DISPLAY MEMORY:
CLEAR MEMORY:
OPTION
DEFAULT:
Auto, Pause, Auto Heater
LOCK:
Splice Lock, Heat Lock, Clear memory Lock, Password Query
PASSWORD:
CALIBRATION
ARC CALIBRATION:
DIAGNOSTIC TEST:
DUST TEST:
LED TEST:
test a LED brightness.
MOTOR DRIVE:
ELECTRODE
ELECTRODE CAUTION:
ELECTRODE USED:
ELECTRODE REPLACE:
ELECTRODE STABILIZE:
CLEAR ARC COUNT:
display a splicing data and image.
erase the whole data.
change a password.
calibrate an arc power.
test the status of the K33A components
test the optical path for dust impairment
Test the K33A system motors manually.
set a caution message for replacement
display an arc count number.
display warning message.
stabilize an arc discharge current.
erase an arc count number.