Fault
Only soda is being
dispensed
Only syrup is being
dispensed
Soda/syrup ratio is
incorrect
Cornelius Deutschland GmbH
Document no. TD1001000
Version 01/10/2019, Index 4
Probable cause
Syrup container is empty
Connections on the syrup contain-
er are not properly connected
CO
feed pressure for the syrup
2
circuit is set incorrectly on the rele-
vant pressure-reducing valve
Syrup tube is not connected to the
syrup container
Syrup tube is contaminated
Incorrectly set valve on the tower
Defective valve on the tower
Shut-off valve or pressure-reduc-
ing valve for the fresh water supply
is closed
Water pressure too high or too low Check the water pressure on the
Circulation pump is switched off
Circulation pump is defective
Carbonator pump is switched off
Carbonator pump is defective
Water in the cooling coils is frozen Please contact your service part-
Too little/too much soda
Too little/too much syrup
CO
feed pressure for the syrup
2
circuit is set incorrectly on the rele-
vant pressure-reducing valve
Errors and malfunctions
Remedy
Connect a new syrup container;
see chapter 4.2
Connect the connections on the
syrup container properly (see doc-
umentation on the syrup contain-
er)
Adjust the CO
feed pressure to
2
the required value (see documen-
tation on the CO
system)
2
Connect the syrup tube; see chap-
ter 4.2
Please contact your service part-
ner
Please contact your service part-
ner
Please contact your service part-
ner
Open the shut-off valve and pres-
sure-reducing valve for the fresh
water supply (see documentation
on the drinking water system)
pressure-reducing valve and ad-
just, if necessary; see chapter 4.1
Switch on the circulation pump;
see chapter 4.1
Please contact your service part-
ner
Switch on the carbonator pump;
see chapter 4.1
Please contact your service part-
ner
ner
Please contact your service part-
ner
Please contact your service part-
ner
Adjust the CO
feed pressure to
2
the required value (see documen-
tation on the CO
system)