Errors and malfunctions
NOTICE!
All installation, maintenance and repair work at the unit is to be carried out
by an expert only.
6.1
Troubleshooting table
Fault
Unable to dispense No mains/power supply connected Please contact your service part-
Beverage is too
warm and the com-
pressor is not run-
ning
Beverage is too
warm and the com-
pressor is running
Beverage foams for
all brands
Operator manual Undercounter cooler
Energize 1 HC
24
Probable cause
Transformer defective
Fuse defective
Undercounter cooler is not
switched on
Compressor not running
Excessive beverage dispensing
Condenser is dirty or covered
Agitator motor is defective
Circulation pump is defective
All beverages are too warm
CO
feed pressure for the soda cir-
2
cuit is too high on the relevant
pressure-reducing valve
Syrup has been stored too long
and has had CO
added
2
Contaminated tubes
Errors and malfunctions
Remedy
ner
Please contact your service part-
ner
Please contact your service part-
ner
Start up the undercounter cooler;
see chapter 4.1
Switch on the compressor; see
chapter 4.1
Please contact your service part-
ner
Do not exceed the maximum dis-
pensing capacity (see the docu-
ment "Undercounter cooler
operator manual")
Please contact your service part-
ner
Please contact your service part-
ner
Please contact your service part-
ner
Check storage temperature
Adjust the CO
feed pressure to
2
the required value (see documen-
tation on the CO
system)
2
Connect a new syrup container;
see chapter 4.2
Please contact your service part-
ner