Advertisement

DANGER!
Risk of personal injury and equipment damage due to leaking refrig-
erant!
In accordance with DIN EN 378 standard, part 1, the refrigerant used with
this unit, R290 (propane), is classified as safety group A3. It is not poison-
ous and not caustic or corrosive. However, it is combustible and highly
flammable. As a result, a potentially explosive atmosphere may occur in the
case of leaks. The refrigerant is heavier than air and, consequently, accu-
mulates at the bottom and may enter lower lying areas (e.g. sewage sys-
tems). At high concentrations, this may lead to a lack of oxygen, resulting
in a risk of suffocation. Lower concentrations may have a narcotic effect.
The refrigerant has a very slight, somewhat sweet smell.
NOTICE!
In particular, safety standards are to be observed in their scope of validity
(e.g. EN 60335-2-75).
Cornelius Deutschland GmbH
Document no. TD1001000
Version 01/10/2019, Index 4
Avoid any damage to components that carry the refrigerant.
If you suspect any leaks, however small, shut down the unit, air the
room well and inform your service partner.
Do not allow direct contact with the skin of any leaking refrigerant.
Fire, open flames and smoking are prohibited.
If you begin to notice any smell, leave the room and alert the fire ser-
vice.
Operator manual Undercounter cooler
Energize 1 HC
Safety
9