Visually Inspecting The Unit - Cornelius Energize 1 HC Series Operator's Manual

Undercounter cooler
Hide thumbs Also See for Energize 1 HC Series:
Table of Contents

Advertisement

5.2

Visually inspecting the unit

NOTICE!
Working with a shut off water pipe means the python and the carbonator
tank will be empty and therefore not dispense. The soda circuit requires
careful bleeding using the carbonator tank drain valve.
1. Check the water level gauge to make sure the water pan is filled up with tap water.
Make sure the water level is between minimum and maximum.
If necessary, fill up the water bath with tap water.
2. Check that the CO
If necessary, open the valve on the CO
3. Check the pressure-reducing valve on the CO
bonation is set as specified (for the setpoint, see chapter 3.3).
4. Only for types with CO
valve on the CO
2
is set as specified (for the setpoint, see chapter 3.3).
5. Check that the CO
If necessary, open the CO
6. Check that the water supply valve is open; see documentation on the water supply valve.
If necessary, open the water supply valve.
7. Check the pressure-reducing valve on the water pip to make sure the water pressure is
set as specified (for the setpoint, see chapter 3.3).
8. Check the fill level and the connection of the syrup containers and BIBs and replace the
empty containers with full ones; see chapter 4.2.
9. Check the tightness of the basic ingredient/beverage tubes for any leaks. They can only
be visually inspected.
If there are any fluids leaking out, please inform your service partner.
10. Check the tightness of the CO
The initial pressure indicator on the pressure-reducing valve must not drop; if it does, in-
form your service partner immediately!
11. Afterwards, open the CO
12. Inspect the unit for damage.
Always replace any damaged components and parts.
Please contact your service partner.
Operator manual Undercounter cooler
Energize 1 HC
22
bottle valve is open; see documentation on the CO
2
-operated syrup pumps: Check the second pressure-reducing
2
bottle to make sure the CO
shut off valves are open; see documentation on the CO
2
shut off valves.
2
tubes by closing the valve on the CO
2
bottle valve again.
2
bottle.
2
bottle to make sure CO
2
pressure for pressurising the syrup pumps
2
Maintenance
system.
2
pressure for car-
2
system.
2
bottle.
2
Cornelius Deutschland GmbH
Document no. TD1001000
Version 01/10/2019, Index 4