Stripping and crimping machine
5.

Technical specifications

Drive................................................................................................................................ Electric motor
Power supply .............................................................................................................. 1~230 V / 50 Hz
Power consumption .................................................................................................................. 100 VA
Fuse (line filter) ..............................................................................................................2 x T2AH250V
Protecting class..............................................................................................................................IP20
Cycle time ..................................................................................................................................... 1.5 s
Continuous sound level .......................................................................................................< 70 dB(A)
Dimensions
(w x d x h)
Colour ................................................................................................................................... RAL 7021
Weight.......................................................................................................................................... 15 kg
Temperature
Operating .......................................................................................................................+10°C - +45°C
Storage/Transport .......................................................................................................... -20°C - +70°C
Relative humidity
Operating .......................................................................................................5% - 95% (no bedewing)
Storage/Transport ..........................................................................................5% - 95% (no bedewing)
Barometric pressure
Operating ..................................................................................................................... 1080 - 795 hPa
Storage/Transport ........................................................................................................ 1080 - 660 hPa
08-09-19-DK-Operating Manual_gb.doc / 2008-09-19
without reel and holder.................................................(292 x 310 x 260) mm