FLEXIBLE COUPLING, CONNECTORS AND CAST-
ERS
If the unit is to be installed with flexible couplings and /
or quick-disconnect fittings, the installer must use a AGA
design-certified commercial flexible connector of at least
3/4" NPT (with suitable strain relief). The flexible con-
nector must comply with the standard for Connectors for
Movable Gas Appliances, ANSI Z21.69 and addendum
Z21.69a (or latest edition) and a quick-disconnect de-
vice that complies with the standard for quick-disconnect
devices for use with Gas Fuel should comply with ANSI
Z21.41 and addendum Z21.41a (or latest edition). If dis-
connection of the restraint is necessary, make sure to re-
connect restraint after the appliance has been returned
to its originally installed position. Domestic gas or water
connectors are not suitable!*Restraining device may be
attached to the back frame/panel of unit.
If the unit is to be installed with casters, a flexible connec-
tor must be used and the same ANSI standards apply.
Locking front casters are provided to limit the movement
of the appliance without depending on the connector or
associated piping. A suitable strain relief must be installed
with the flexible connector. All connections must be sealed
with a joint compound suitable for LP gas and all connec-
tions must be tested with a soapy water solution before
lighting pilots.
LIGHTING THE OVEN
CAUTION
When lighting pilots and checking for leaks,
do not stand with your face close to the com-
bustion chamber.
All MARKET FORGE INDUSTRIES, INC. appliances are
adjusted and tested before leaving the factory, effectively
matching them to sea level conditions. Adjustments and
calibrations to assure proper operation may be necessary
on installation to meet local conditions; low gas charac-
teristics, to correct possible problems caused by rough
handling or vibration during shipment, and are to be per-
formed only by qualified service personnel. These adjust-
ments are the responsibility of the customer and/or dealer
and are not covered by our warranty. Check all gas con-
nections for leaks with a soapy water solution before light-
ing any pilots.
FINAL PREPARATION
On initial installation, turn the oven to 250 degrees and
operate for about 1 hour, then reset the thermostat to its
maximum and operate for another hour. This will drive off
solvents remaining in the unit. At the end of this second
hour, turn the thermostat OFF, open the door and set the
switch to 'cool'. Oven should then be thoroughly washed
using hot, soapy water before being used.