Step 3 - Ground The Generator; Subsequent Use Of This Generator; Step 1 - Verify Oil Level - Sportsman GEN2000I Instruction Manual

2200 surge watts/1800 running watts gasoline inverter
Hide thumbs Also See for GEN2000I:
Table of Contents

Advertisement

Step 3 - Ground the Generator

Failure to properly ground this generator can result in electrocution.
Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge)
stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass
grounding rod that is driven into the earth.
Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area.

Subsequent Use of this Generator

For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation.
IMPORTANT: Be familiar with the procedures described in the previous section titled "Using the Generator for the First Time" of this
manual. If not, review this section now.

Step 1 - Verify Oil Level

Even though this generator is equipped with an automatic shutoff to protect it from damage due to low oil, it is important to check the oil level in the
engine crankcase before each use to ensure that there is sufficient quantity.
1. Verify that this generator is on a level surface.
2. Unscrew the oil filler/dipstick cap from the engine.
3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.
4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the
dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See "Changing/Adding Oil" in the
"Maintenance/Care" section of this manual).
5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level.
Model GEN2000I Oil Capacity
Model GEN2000I Oil Type Recommended
GEN2000I 2200 Surge Watt / 1800 Running Watt Portable Gasoline Inverter Generator Manual
Figure 3 - Attaching the Grounding Wire to this Generator
13.5 ounces
High Detergent Motor Oil, SAE10W-30