PROBLEM
Main burner flames
are small and
appear lazy; oil does
not come up to
temperature
quickly.
Fryer does not heat.
Fryer is operating
normally, but
recovery is slow
when cooking.
Fryer is operating
normally but
produces a popping
sound when
burners ignite.
Signs of excessive
temperature; oil
scorches and
quickly becomes
discolored.
Fryer will not reach
the temperature
setting and/or runs
erratically.
Fryer oil
temperature cannot
be controlled; fryer
runs at high-limit
temperature.
Controller locks up.
FQ4000 displays
MISCONFIGURED
ENERGY TYPE
FQ4000 displays VAT
ID CONNECTOR NOT
CONNECTED
PROBABLE CAUSES
Improper gas pressure.
A. Gas valve is not turned on.
B. Manual gas shut off valve closed.
C. Improperly connected quick
disconnect fitting on gas line.
D. Ignition module issue
Improper gas pressure.
Dirty or obstructed gas valve vent
tube (non-CE fryers only).
A. Improper gas pressure.
B. Oil used is of inferior quality
and/or oil has been used too
long.
C. Dirty frypot.
A. Incorrect location of temperature
sensor probe or defective
temperature sensor.
B. Loose wiring/wire connection.
Defective temperature probe.
Controller error.
Energy type in fryer setup is
incorrect.
Controller locator missing or
disconnected.
Contact your FAS for service.
A. Turn the gas valve knob to the ON
position.
B. Verify that any in-line manual shut off
and gas main valve is open.
C. Verify that the quick-disconnect fitting
on the flexible gas line is firmly
connected to the fryer.
D. Contact your FAS for service.
Contact your FAS for service.
Clean per instructions in Chapter 4 of this
manual.
A. Contact your FAS for service.
B. Replace oil.
C. Ensure frypot is clean when refilling
with new oil.
A. Contact your FAS for service.
B. Contact your FAS for service.
Contact your FAS for service.
Remove and restore power to the
controller. If problem persists, call your
FAS for assistance.
Ensure that the fryer is configured
properly for the correct energy type.
Ensure the 6-pin locator is connected to
rear of controller and it properly
grounded.
5-3
CORRECTIVE ACTION