2. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the
hood be 24 in. (600 mm) when the appliance consumes more than 120,000 BTU per hour.
3. Test the fryer electrical system:
a. Plug the fryer electrical cord(s) into a grounded electrical receptacle.
b. Place the power switch in the ON position.
Verify that the display indicates the controller is on.
c. Place the fryer power switch in the OFF position. Verify that the display indicates OFF.
4. Refer to the data plate on the inside of the fryer door to determine if the fryer burner is
configured for the proper type of gas before connecting the fryer quick-disconnect device or
piping from the gas supply line.
Fryers MUST be connected ONLY to the gas type identified on the attached rating plate.
5. Verify the minimum and maximum gas supply pressures for the type of gas to be used in
accordance with the accompanying tables and the data plate on the inside of the fryer door.
Non- CE Standard for Incoming Gas Pressure
Fryer Model
Gas Type
Incoming Min Pressure W.C/kpa/mbar
Incoming Max Pressure W.C/kpa/mbar
Burner Manifold Pressure WC/kpa
Orifice Size (mm)
(1) mbar = 10,2 mm H2O
CE Standard for Incoming Gas Pressure
Fryer Model
Gas Type
Incoming Min Pressure (mbar)
Incoming Max Pressure (mbar)
Burner Manifold Pressure (mbar)
Orifice Size (mm)
(1) mbar = 10,2 mm H2O
Australia Standard for Incoming Gas Pressure
Fryer Model
Gas Type
Incoming Min Pressure W.C/kpa/mbar
Incoming Max Pressure W.C/kpa/mbar
Burner Manifold Pressure WC/MJ/h/TPP(kPa)
Orifice Size (mm)
(1) mbar = 10,2 mm H2O
Korea Standard for Incoming Gas Pressure
Fryer Model
Gas Type
Incoming Min Pressure W.C/kpa/mbar
Incoming Max Pressure W.C/kpa/mbar
Orifice Size (mm)
(1) mbar = 10,2 mm H2O
DANGER
FQG120T
Nat
6/1.49/14.93
14.00/3.48/34.84
3.20/0.80
2.04
FQG120T
G20
Natural Gas Lacq
Natural Gas Gronique
20
20
7
2.04
FQG120T
Nat
4.54/1.13/11.30
14.00/3.48/34.84
3.00/73.8/1.0
2.92
FQG120T
LNG (Natural)
4/1.00/10.00
10/2.50/25.00
2.04
2-6
LP
11/2.74/27.37
14.00/3.48/34.84
8.25/2.5
1.30
G25
G30
Butane /Propane
20
28/30
25
10
2.04
1.95
LP
11.05/2.75/27.50
14.00/3.48/34.84
8.25/73.8/2.05
1.95
LPG (Propane)
9.2/2.30/23.00
13.2/3.30/33.00
1.30
G31
Propane
37
50
50
17
20.6
1.95