The duct system, the hood and filter bank must be cleaned on a regular basis and kept free of
grease according to the NFPA Standard No. 96.
A copy of the standard may be obtained from the National Fire Protection Association, Battery
March Park, Quincy, MA 02269 or at www.NFPA.org.
Never use the interior of the fryer cabinet for storage or store items on shelving over or behind the
fryer. Exhaust temperatures can exceed 650°F (343°C) and may damage or melt items stored in or
near the fryer.
2.1.2 National Code Requirements
The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside
of the fryer door. Connect a fryer stamped "NAT" only to natural gas, those stamped "PRO" only to
propane gas, and those stamped "MFG" only to manufactured gas.
Installation shall be made with a gas connector that complies with national and local codes, and,
where applicable, CE codes. Quick-disconnect devices, if used, shall likewise comply with national,
local, and, if applicable, CE codes. In the absence of local codes, installation must conform to the
national Fuel Gas Code, ANSI Z223.1/NFPA 54, ANSIZ83.11, NFPA96,211 or the Natural Gas and
Propane Installation code, CSA B149.1, as applicable including:
1.
The appliance and its individual shutoff valve must be disconnected form the gas supply
piping system during any pressure testing of the system at test pressures in excess of ½ psi
(3.5 kPa).
2.
The appliance must be isolated from the gas supply piping system by closing its individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
2.1.3 Power Requirements
Frymaster FQG120T gas fryers require 120VAC 60 Hz or 230VAC single-phase 50 Hz (International)
electrical service and are equipped with a 16-3 SJT grounded flexible power cord for a direct
connection to the power supply. Amperage draw for each unit depends on the accessories
supplied with the unit/system.
This appliance must be connected to a power supply having the same voltage and phase
as specified on the rating plate located on the inside of the appliance door.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar-
ly qualified persons in order to avoid a hazard.
2.1.4 Electrical Grounding Requirements
All electrically operated appliances must be grounded in accordance with all applicable national
and local codes, and, where applicable, CE codes. In the absence of local codes, the appliance must