SKELECT05 ELECT
WARNING! ENSURE PUMP IS ISOLATED FROM
ELECTRICITY AND WATER SUPPLY. IF IN
DOUBT CONSULT A COMPETENT
TRADESMAN.
Pump should be serviced in horizontal
position with couples disconnected and water
and electricity supply isolated.
DO NOT RUN PUMP DRY. ALLOW WATER TO
FILL PUMP TO LUBRICATE SEALS BEFORE
STARTING. CHECK FOR LEAKS DURING TEST
BEFORE BEING SATISFIED PUMP IS OK
Document SSI.10 December15. Issue 1
Salamander Pumps Shower Systems Limited
Unit 2c Colima Avenue, Enterprise Park West,
Sunderland, SR5 3XE
Telephone:
0191 516 2002
Facsimile:
0191 548 4445
Email: sales@salamanderpumps.co.uk
www.salamanderpumps.co.uk
PLEASE NOTE:
By using the parts included in this pack to repair your pump, you will
be invalidating any warranty you have on the pump.
Returns:
If you need to return this pack for any reason please ensure the
original packaging and these instructions leaflets are returned also.
If you have any questions or queries regarding this spares pack or
any other pump related questions please contact us.
UK:
Salamander Pumped Shower Systems Limited
Unit 2c, Colima Avenue Enterprise Park West
Sunderland SR5 3XE
Tel: 0191 516 2002
Email: tech@salamanderpumps.co.uk
Eire:
MTA agencies Ireland Fearn House,
Unit 4 Jamestown Business Park
Jamestown Road Finglas,
Dublin 11
Tel: +353 (0)1 864 3363
Email: service@mtagencies.ie
Instructions VIDEOLINK:

INTRODUCTION

All positive head FORCE PUMPS

Tools required :

• PZ2 Screwdriver
• 7mm Deep Socket
• Long nose Pliers
• Snips

Parts in Service kit:

• Float- PFLOAT02(12) x 2
• NRV- CNRVPL01 (14) x 2
• Hall Effect sensor - EHALLE01 (19) x 2
• Cable Tie- FCABLE01(33) x 2
• Interface -EPCBUN02 (9) x 1
• Screw No:6 x 1/2" (11) X 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SKELECT05 ELECT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Salamander Pumps SKELECT05 ELECT

  • Page 1 Instructions VIDEOLINK: Salamander Pumps Shower Systems Limited SKELECT05 ELECT INTRODUCTION Unit 2c Colima Avenue, Enterprise Park West, Sunderland, SR5 3XE Telephone: 0191 516 2002 All positive head FORCE PUMPS Facsimile: 0191 548 4445 Email: sales@salamanderpumps.co.uk Tools required : • PZ2 Screwdriver www.salamanderpumps.co.uk...
  • Page 2 SKELECT05 SERVICE INSTRUCTIONS: 1. Remove NRV(14) from OUTER(3) using long nosed pliers and discard. 2. Remove float(12) noticing its orientation. 3. Repeat above steps for opposite pump side if required. 3. Remove Junction Box (JB) lid screws (11) using PZ2 screwdriver and retain 4.

Table of Contents