Low-cost oem process meter, 0-20, 4-20 ma, 0-5, 1-5, 0-10, ±10 v inputs, input current overload protection, nema 4x, ip65 front, shallow depth 1/8 din case 3.6" behind panel, 4 digit display, 0.56" 14 mm high, red leds, easy front panel programming, scale (4 pages)
Explosion-proof loop-powered feet & inches level meter (25 pages)
Summary of Contents for PRECISION DIGITAL SABRE P PD603
Page 1
Scale without a Signal Source • Calibrate with a Signal Source • Maximum/Minimum Display • Universal Power Supply 85-265 VAC • 12-36 VDC/12-24 VAC Power Option • 24 VDC @ 200 mA Transmitter Supply Option PRECISION DIGITAL CORPORATION 1.800.561.8187 information@itm.com www. .com...
Disclaimer The information contained in this document is subject to change without notice. Precision Digital makes no representations or war- ranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose.
Sabre P Model PD603 Process Meter Instruction Manual Table of Contents INTRODUCTION ------------------------------------------------------------ 2 ORDERING INFORMATION --------------------------------------------- 2 SPECIFICATIONS ---------------------------------------------------------- 5 General ------------------------------------------------------------------------------- 5 Process Input ---------------------------------------------------------------------- 6 COMPLIANCE INFORMATION ----------------------------------------- 7 Safety --------------------------------------------------------------------------------- 7 Electromagnetic Compatibility ----------------------------------------------- 7 SAFETY INFORMATION ------------------------------------------------- 8 INSTALLATION ------------------------------------------------------------- 9 Unpacking --------------------------------------------------------------------------- 9 Panel Mounting -------------------------------------------------------------------- 9...
Page 4
Sabre P Model PD603 Process Meter Instruction Manual Troubleshooting Tips --------------------------------------------------------- 29 QUICK USER INTERFACE REFERENCE GUIDE ---------------- 30 EU DECLARATION OF CONFORMITY ----------------------------- 31 Table of Figures Figure 1. Panel Cutout and Mounting ..........9 Figure 2. Connector Labeling - Meter with 24 V Supply ....10 Figure 3.
Sabre P Model PD603 Process Meter Instruction Manual SPECIFICATIONS Except where noted all specifications apply to operation at +25°C. General DISPLAY 0.56" (14 mm) high, red LED Four digits (-1999 to 9999), automatic lead zero blanking. DISPLAY 5/second UPDATE RATE 9999 OVERRANGE Display flashes...
Sabre P Model PD603 Process Meter Instruction Manual COMPLIANCE INFORMATION Safety UL LISTED USA and Canada UL 508 Industrial Control Equipment UL FILE NUMBER E160849 FRONT PANEL UL Type 4X, NEMA 4X, IP65; panel gasket provided LOW VOLTAGE EN 61010-1:2010 DIRECTIVE Safety requirements for measurement, control, and laboratory use...
Sabre P Model PD603 Process Meter Instruction Manual Note: Testing was conducted on PD603 meters installed through the co- vers of grounded metal enclosures with cable shields grounded at the point of entry representing installations designed to optimize EMC performance. SAFETY INFORMATION CAUTION: Read complete WARNING: Risk of...
Sabre P Model PD603 Process Meter Instruction Manual INSTALLATION There is no need to remove the meter from its case to com- plete the installation, wiring, and setup of the meter. Unpacking Remove the meter from box. Inspect the packaging and con- tents for damage.
Sabre P Model PD603 Process Meter Instruction Manual Connections All connections are made to removable screw terminal connectors located at the rear of the meter. Use copper wire with 60°C or 60/75°C insulation for all line voltage connections. Observe all safety regulations.
Sabre P Model PD603 Process Meter Instruction Manual Signal Connections Signal connections are made to a five-terminal connector labeled SIGNAL on Figure 2. The COM (common) terminal is the return for all types of input signals. Current and Voltage Connections The following figures show examples for current and voltage connections.
Sabre P Model PD603 Process Meter Instruction Manual SIGNAL CONNECTOR 24V OUT SIGNAL CONNECTOR Signal 3-Wire Voltage Voltage Signal Transducer Figure 6. Voltage Input Connections The meter is capable of accepting any voltage from -10 VDC to +10 VDC. 1.800.561.8187 information@itm.com www.
Sabre P Model PD603 Process Meter Instruction Manual SETUP AND PROGRAMMING • There is no need to recalibrate the meter when first received from the factory. • The meter is factory calibrated prior to ship- ment, for all input types, in milliamps and volts.
Sabre P Model PD603 Process Meter Instruction Manual Front Panel Buttons and Status LED Indicators 9. 6 03 Button Description Symbol Menu Right arrow/Reset Up arrow/Max Enter/Ack • Press the Menu button to enter or exit the Programming Mode at any time.
Sabre P Model PD603 Process Meter Instruction Manual Display Functions and Messages The meter displays various functions and messages during setup/pro- gramming and operation. The following table shows the displayed func- tions and messages with their action/setting description. Display Parameter Action/Setting setu Setup...
Sabre P Model PD603 Process Meter Instruction Manual Main Menu The main menu consists of the following functions: Setup, Program, and Password. • Press Menu button to enter Programming Mode then press Up ar- row button to scroll main menu. Mode 9603 setu...
Sabre P Model PD603 Process Meter Instruction Manual Setting Numeric Values The numeric values are set using the Right and Up arrow buttons. Press Right arrow to select next digit and Up arrow to increment digit value. The digit being changed is displayed brighter than the rest. Press the Enter/Ack button, at any time, to accept a setting or Menu button to exit without saving changes.
Sabre P Model PD603 Process Meter Instruction Manual Setting Up the Meter (setu) The Setup menu is used to select: Input signal the meter will accept Decimal point position Press the Enter/Ack button to access any menu or press Up arrow but- ton to scroll through choices.
Sabre P Model PD603 Process Meter Instruction Manual Setting the Decimal Point (dec. p ) Decimal point may be set with up to three decimal places or with no decimal point at all. Pressing the Up arrow moves the decimal point one place to the right until no decimal point is displayed, then it moves to the leftmost position.
Sabre P Model PD603 Process Meter Instruction Manual Programming the Meter (prog) It is very important to read the following information, before proceeding to program the meter: • There is no need to recalibrate the meter when first received from the factory.
Sabre P Model PD603 Process Meter Instruction Manual Scaling the Meter (ScAL) The process inputs (4-20 mA and ±10 VDC) can be scaled to display the process in engineering units. A signal source is not needed to scale the meter; simply program the in- puts and corresponding display values.
Page 22
Sabre P Model PD603 Process Meter Instruction Manual Error Message (Err) An error message indicates that the calibration or scaling process was not successful. After the error message is displayed, the meter reverts to input 1, allow- ing the appropriate input signals to be applied. The error message might be caused by any of the following conditions: Input signal is not connected to the proper terminals or it is con- nected backwards.
Sabre P Model PD603 Process Meter Instruction Manual Calibrating the Meter (Cal) To scale the meter without a signal source refer to Scaling the Meter (ScAL), page 21. The meter can be calibrated to display the process in engineering units by applying the appropriate input signal and following the calibration procedure.
Sabre P Model PD603 Process Meter Instruction Manual Setting Up the Password (pass) The Password menu is used to program a four-digit password to pre- vent unauthorized changes to the programmed parameter settings. Locking the Meter Enter the Password menu and program a four-digit password. For instructions on how to program numeric values see Setting Numeric Values, page 17.
Page 25
Sabre P Model PD603 Process Meter Instruction Manual Entering the correct four-digit number sets the password to 0000, disa- bling the protection. Changes to the programmed parameter settings are allowed only with the password set to 0000. If the password entered is incorrect, the meter displays LoCd (Locked) for about two seconds, then it returns to Run Mode.
Sabre P Model PD603 Process Meter Instruction Manual OPERATION For process inputs, the meter is capable of accepting positive and nega- tive signals and displaying these signals in engineering units from -1999 to 9999 (e.g. a signal from -10 to +10 VDC could be displayed as -5000 to 5000).
Sabre P Model PD603 Process Meter Instruction Manual Maximum/Minimum Readings The main function of the front panel buttons during operation is to dis- play the maximum and minimum readings reached by the process. Actual Reading 9603 9859 Press Up to Display and Toggle Max/Min Press Enter to Hold Max/Min Press Right to Reset Max/Min...
Sabre P Model PD603 Process Meter Instruction Manual MOUNTING DIMENSIONS 1.76" (45mm) 2.45" (62mm) 3.2" 0.59" (81mm) (15mm) 3.6" (91mm) Figure 7. Meter Dimensions - Side View Figure 8. Case Dimensions - Top View 1.800.561.8187 information@itm.com www. .com...
Sabre P Model PD603 Process Meter Instruction Manual TROUBLESHOOTING The rugged design and the user-friendly interface of the meter should make it unusual for the installer or operator to refer to this section of the manual. Troubleshooting Tips Symptom Check/Action Check power at power connector No display at all Meter is locked, enter correct four-digit...
Sabre P Model PD603 Process Meter Instruction Manual QUICK USER INTERFACE REFERENCE GUIDE Display Run Mode Max/Min Setup Input 4-20 mA Program 0-10 V Password dddd Decimal Locked Unlocked Point d . ddd dd . dd Scale ddd . d To Program Calibrate Password...
EN 55011:2009+A1:2010, EN 61000-6- 2:2005, EN 61010-1:2010, and EN 61326:2013 and there were no major technical changes affecting the latest technical knowledge for the products listed above. Product Markings: Signed for and on behalf of Precision Digital Corporation: Name: Jeffrey Peters Company:...
Page 32
Sabre P Model PD603 Process Meter Instruction Manual LIM603_E SFT031 Ver 3.2 & up 04/16 1.800.561.8187 information@itm.com www. .com...