Danfoss ERC 112 User Manual page 24

Electronic refrigeration controller
Hide thumbs Also See for ERC 112:
Table of Contents

Advertisement

User Guide | ERC 112 Refrigeration Controller
"HAr"
HW version
Danfoss hardware version number.
"onL"
OrderNoLow
Danfoss order code number.
"onH"
OrderNoHigh
Danfoss order code number.
"oEL"
OEM code Low
"oEn"
OEM code Middle
"oEH"
OEM code High
"PAr"
Parameter version
OEM parameter version number [requires EKA copy key update].
"CHd"
Manufacturing date
Programme date WWY: week number and year number (2010-19).
"SFC"
Set as Default
Resets all parameters to last good OEM settings.
"Ctt"
Condenser Temp
Temperature of the condensor sensor.
"Et1"
Evaporator1 Temp
Temperature of the evaporator sensor1.
"Et2"
Evaporator2 Temp
Temperature of the evaporator sensor2.
"AuS"
AUX Temp.
Temperature of the AUX sensor. invisible.
"LLu"
Light level value
Actual light level value from light sensor.
"Pir"
Motion sensor state
"att"
Raw Sair Temp
"ESS"
External ECO switch state
Display messages
"unP"
Device is unprogrammed (relay output is locked)
"Prg"
Device has not finished programming (relay output is locked)
"Eco"
Device is in Eco mode
"SC"
Device is in pull-down mode (super-chill)
"dEF"
Device is defrosting
"HoL"
Device is in Holiday mode