Crosstalk

Signal applied to Line Input of a mono channel, and routed to specified output by shortest path. All controls set flat, out or at unity
gain as appropriate. Pan set to full left or right.
Measurement
Channel Muting
Maximum Fader Attenuation
Pan pot Isolation
Routing
Channel to Main Mix
Routing
Channel to Track Buses
Mic Input

Overall Console Noise

Measured at main outputs, channels routed as required with pans / balance controls centred, using Line input with termination. All
controls set flat, out or at unity gain as appropriate, channel and master faders calibrated for 0dB.
Measurement
Line to Mix
(Pan to centre)

Environmental Requirements

Temperature range:
Operating:
+1 to 30 °C (+34 to 86 °F).
Storage:
-20 to 50 °C (-4 to 122 °F).
ORIGIN User Guide
Conditions
20 Hz to 20 kHz
20 Hz to 20 kHz
20 Hz to 20 kHz
Channel routed to all buses apart from one under test
Channel not routed
-50dBu applied to Mic Input at maximum gain, measured at
Direct Output, Monitor path selected
Conditions
1 channel routed
16 channels routed
24 channels routed
32 channels routed
Appendix C
Value
<-100 dB
<-89 dB
<-55 dB
<-94 dB from 20 Hz to 20 kHz
<-64dB from 20 Hz to 20 kHz
<-113dB from 20 Hz to 20 kHz
<-95 dB
Value
<-93 dBu
<-85 dBu
<-83 dBu
<-80 dBu